{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C16Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C16Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C16Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C16Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV6A0C16Q6 modular AC drive, 160 kW normal duty / 132 kW heavy duty at 690 V, 195 kVA / 165 kVA apparent power, STO SIL 3, cabinet mount.","salesMarkdown":"## 160 kW at 690 V — normal vs heavy duty This ATV6A0C16Q6 is the 160 kW normal-duty variant of the Altivar Process ATV600 family, rated 132 kW in heavy-duty mode — both at 690 V supply. The line current draws 163 A normal duty, 138 A heavy duty, with apparent power of 195 kVA and 165 kVA respectively. That heavy-duty ceiling means the drive handles 132 kW continuous without tripping on overload, useful for constant-torque loads like conveyors or extruders where the margin matters. The drive accepts both synchronous and asynchronous motors, so it covers induction machines and permanent-magnet motors on the same unit — no hardware swap needed between motor types. ## Safety function and standards compliance The drive also carries IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), and IEC 60721-3 (environmental) compliance, covering the full machinery directive stack for a CE-marked panel. The integrated EMC filter meets category C3 per IEC 61800-3, supporting up to 300 m (984.3 ft) of motor cable without an external output filter — that's enough for most pump and fan installations in industrial buildings. Total harmonic current distortion (THDI) stays below 48 % at full load. ## Fieldbus and control wiring The base unit ships with Modbus serial (2-wire RS 485, RTU frame, 1-247 addresses) and Modbus TCP via the Ethernet port at 10/100 Mbit/s. Slot A accepts plug-in communication modules for Profibus DP V1, PROFINET, DeviceNet, EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). That means the drive fits into any major fieldbus architecture without a gateway — just the right option card. The line-side connection uses a screw terminal; the motor connection uses M10 x 2 bars — no crimp lugs needed on the motor side, just ring terminals. ## Mounting, cooling, and environmental limits Cabinet-mount only — UL type 1 or type 12 enclosure integration per UL 61800-5-1. Forced convection cooling keeps the power stage within limits; the switching frequency is adjustable from 2 to 4.9 kHz, but expect derating above the default. Operating altitude is up to 2000 m with current derating starting above 1000 m — factor this into the installation if the panel sits at elevation. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz per IEC 60068-2-6. Shock resistance is 4 gn for 11 ms per IEC 60068-2-27. The pollution degree is 2 per IEC 61800-5-1, meaning non-conductive pollution only — keep the cabinet clean or add filtration. Noise level is 69 dB per 86/188/EEC — audible in a quiet control room but typical for a drive of this power class. The kit composition includes the control unit, mechanical mounting kits, power connection set, fuses, and the 200 kW power module.","metaTitle":"Schneider ATV6A0C16Q6 Altivar Process VFD, 160 kW ND, 690 V","metaDescription":"Schneider Electric ATV6A0C16Q6 Altivar Process ATV600 AC drive, 160 kW normal duty at 690 V, 132 kW heavy duty. STO SIL 3, integrated EMC filter C3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"163.0 A 690 V normal duty) 138.0 A 690 V heavy duty)","Frequency":"50...60 Hz - 5...5 %","Product Status":"Active","Pollution Degree":"Pollution degree 2","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.1 °C","Temperature Storage":"-40...158 °F (-40...70 °C)","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6A0C16Q6/variable-speed-drive-altivar-process-atv600-apm-single-690-v-160-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C16Q6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C16Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C16Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}