{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C20N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C20N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C20N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C20N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular drive, ATV6A0C20N6, 132 kW at 500 V normal duty / 110 kW heavy duty, integrated EMC filter C3, forced convection cooling, STO SIL 3.","salesMarkdown":"## Building the BOM around this drive Cabinet mount only — no through-panel gland plate kit in the box. The kit includes one control unit, one power module (200 kW size), mechanical mounting hardware, and a set of fuses. Line-side connection uses M10 screw bars; control uses removable screw terminals 0.5–1.5 mm² (AWG 20–16). Cooling is forced convection; ambient derating above 40 °C (not stated explicitly but typical for this range). Operating altitude up to 1000 m without derating; above that, reduce current per the drive's thermal curve. Pollution degree 2 per IEC 61800-5-1, so standard office/light industrial environment acceptable. Safe torque off (STO) certified to SIL 3 — no need for an external safety relay if the control system provides a dual-channel STO signal. Motor protection includes thermal, phase break, short-circuit, and ground fault detection. Communication slot A accepts fieldbus modules for PROFIBUS DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen. The base drive includes Modbus serial (RS-485, 2-wire, RTU) and Modbus TCP (Ethernet). If the control network is one of those, no extra module needed.","metaTitle":"Schneider ATV6A0C20N6 ATV600 Process Drive, 132 kW / 110 kW","metaDescription":"Altivar Process ATV600 drive, 132 kW normal / 110 kW heavy duty at 500 V. Integrated EMC filter C3, STO SIL 3, modular version. Current active. Source to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV6A0C20N6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"69 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 500 V, 132 kW","Line current":"183.0 A 500 V normal duty) 154.0 A 500 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"158 kVA at 500 V normal duty 133 kVA at 500 V heavy duty","Motor power kW":"132.0 kW at 500 V normal duty 110.0 kW at 500 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 3590 W 2.5 kHz normal duty) Forced convection 2940 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"215.0 A at 2.5 kHz normal duty 175.0 A at 2.5 kHz heavy duty","Maximum transient current":"236.5 A 60 s normal duty) 262.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6A0C20N6/variable-speed-drive-altivar-process-atv600-apm-single-500-v-132-kw/"},"ai":{"faq":[{"question":"What is the CE marking on this drive?","answer":"The ATV6A0C20N6 carries CE marking, confirming compliance with applicable EU directives."},{"question":"What does 'Modular version' mean?","answer":"The drive is supplied as separate power module and control unit, plus mounting hardware and line fuses. The control unit and power module must be assembled together — not a single-block unit."},{"question":"What compliance documentation is available for this part?","answer":"The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. It is CE marked and includes integrated EMC filter C3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C20N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C20N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}