{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C20R4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C20R4","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C20R4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C20R4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular VFD, 200 kW at 440 V normal duty / 160 kW heavy duty, STO SIL 3, integrated EMC filter C3, cabinet mount.","salesMarkdown":"## Drive selection memo — ATV6A0C20R4 The Schneider ATV6A0C20R4 is an Altivar Process ATV600 modular drive rated for 200 kW at 440 V normal duty and 160 kW heavy duty, with corresponding line currents of 325 A and 269 A. It carries STO SIL 3 as a standard safety function and integrates an EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m. The lifecycle stage is current, so this is the production variant to specify for new builds or critical spares. ## Control supply and I/O architecture The control section requires an external 24 V DC supply (19...30 V) for the digital inputs, plus a separate internal 24 V DC rail (21...27 V, <200 mA) for the digital inputs and STO circuit, with overload and short-circuit protection built in. A 10.5 V DC reference supply is provided for a 1 to 10 kOhm potentiometer. The six digital inputs (DI1–DI6) are programmable, with DI5 and DI6 capable of 0–30 kHz pulse input. Three analog inputs (AI1–AI3) are software-configurable for voltage (0–10 V DC, 30 kOhm) or current (0–20 mA / 4–20 mA, 250 Ohm), all 12-bit resolution. Two analog outputs (AO1, AO2) are also present. Three configurable relay outputs (R1–R3) handle fault and sequence signalling, each rated for 100,000 cycles. ## Option card slots and fieldbus Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slot A and slot B can also accept digital/analog I/O extension modules or output relay extension modules. The drive ships with a Modbus serial port (2-wire RS 485, RTU frame, 4.8 to 38.4 kbit/s) and an Ethernet port for Modbus TCP (10/100 Mbit/s, half/full duplex, autonegotiation). The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Pollution degree 2 per IEC 61800-5-1. Operating altitude up to 1000 m without derating, then 1 % per 100 m to 4800 m. Ambient humidity 5–95 % non-condensing. Shock resistance 7 gn for 11 ms. Noise level 70 dB. Forced convection cooling. Cabinet mount, modular variant.","metaTitle":"Schneider ATV6A0C20R4 Altivar Process ATV600, 200 kW, STO SI","metaDescription":"Schneider ATV6A0C20R4 Altivar Process ATV600 drive, 200 kW at 440 V normal duty, 160 kW heavy duty, STO SIL 3, integrated EMC filter C3, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6A0C20R4","Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection","Marking":"CE","Variant":"Modular version","Accuracy":"+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"70 dB conforming to 86/188/EEC","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 440 V, 200 kW","Line current":"325.0 A at 440 V (normal duty) 269.0 A at 440 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Refresh time":"Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"248 kVA at 440 V normal duty 205 kVA at 440 V heavy duty","Motor power kW":"200.0 kW at 440 V normal duty 160.0 kW at 440 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2 power module 160 kW 1 front cover","Linearity error":"AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output","Protection type":"Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Local signalling":"3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"7 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles","Sampling duration":"2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Analogue input type":"AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits","Discrete input type":"DI1...DI6 programmable, 24 V DC ( DI5, DI6 programmable as pulse input: 0...30 kHz, 24 V DC ( STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Input compatibility":"DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2","Number of addresses":"1...247 for Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Analogue output type":"Software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits","Discrete input logic":"Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars","Power dissipation in W":"Forced convection: 4790 W, switching frequency 2.5 kHz (normal duty) Forced convection: 3790 W, switching frequency 2.5 kHz (heavy duty)","IP degree of protection":"IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"370.0 A at 2.5 kHz normal duty 302.0 A at 2.5 kHz heavy duty","Maximum switching current":"Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC","Maximum transient current":"407 A during 60 s (normal duty) 453 A during 60 s (heavy duty)","Minimum switching current":"Relay output R1, R2, R3: 5 mA at 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"440 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6A0C20R4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6A0C20R4.pdf', 'path_name': 'd32b4cce08ce092c8df94cc5eadc5514.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/d32b4cce08ce092c8df94cc5eadc5514.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6A0C20R4/variable-speed-drive-altivar-process-atv600-apm-single-440-v-200-kw/"},"ai":{"faq":[{"question":"What are the key motor power ratings for the ATV6A0C20R4?","answer":"It is rated for 200 kW at 440 V normal duty and 160 kW at 440 V heavy duty, with corresponding line currents of 325 A and 269 A."},{"question":"What safety function does this drive include?","answer":"It includes Safe Torque Off (STO) rated to SIL 3."},{"question":"What fieldbus options are available for the ATV6A0C20R4?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen modules. It also has built-in Modbus serial (RS 485) and Ethernet Modbus TCP ports."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C20R4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C20R4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}