{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C35R4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C35R4","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C35R4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C35R4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular drive, 355 kW at 440 V normal duty / 280 kW heavy duty, 559 A line current, integrated EMC filter C3 to 300 m, STO SIL3, CE marked.","salesMarkdown":"The ATV6A0C35R4 is a modular Altivar Process ATV600 drive rated for 355 kW at 440 V in normal duty and 280 kW in heavy duty, with a corresponding line current of 559 A at 440 V (normal) or 450 A (heavy). That makes it the right fit for a 355 kW motor on a process pump or fan, and the heavy-duty rating handles the higher current demand of a constant-torque load like a conveyor without oversizing the drive. It ships as a kit: one control unit, three 160 kW power modules, front covers, mounting hardware, and power connections. That modular build means if a power module takes a hit, you swap just that section — not the whole drive. No shop, no crane, fix it where it sits. On the safety front it carries STO (Safe Torque Off) rated SIL 3, plus thermal, overcurrent, short-circuit, and ground-fault protections on both motor and drive sides. Any safety-instrumented system specifying SIL 3 can land here without an external safety relay for the torque-off function. ## Power supplies and control wiring Digital inputs need an external 24 V DC supply (19…30 V). The drive also provides an internal 24 V DC supply for digital inputs and STO (21…27 V, <200 mA) with overload and short-circuit protection — so if your control voltage is stable, you can power the inputs from the drive itself and save an external PSU. There's a separate 10.5 V DC reference supply for the potentiometer (1 to 10 kOhm). Analog inputs: software-configurable 0…10 V DC or 0/4…20 mA, 12-bit resolution. Sampling time 5 ms ±0.1 ms per input. Cabinet mount only, forced-convection cooling. Pollution degree 2 per IEC 61800-5-1 means it expects a clean indoor environment — no conductive dust or condensation. The kit composition includes three 160 kW power modules — so if one fails, you can replace it individually rather than the whole drive. Keep a spare power module on the van for quick field swaps; the control unit and front covers are separate line items if needed.","metaTitle":"Schneider Electric ATV6A0C35R4 Altivar Process 600, 355 kW","metaDescription":"Active ATV6A0C35R4 modular drive, 355 kW at 440 V normal duty, 280 kW heavy duty. Integrated C3 EMC filter to 300 m, STO SIL3. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"559.0 A at 440 V (normal duty) 450.0 A at 440 V (heavy duty)","Frequency":"50...60 Hz - 5...5 %","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.1 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV6A0C35R4/variable-speed-drive-altivar-process-atv600-apm-single-440-v-355-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C35R4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C35R4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C35R4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}