{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C40N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C40N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C40N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C40N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV6A0C40N6 modular cabinet-mount AC drive, 280 kW at 500 V normal duty, 220 kW heavy duty, 329 kVA, with integrated EMC filter C3, STO SIL 3, Modbus serial.","salesMarkdown":"## 280 kW at 500 V — normal-duty and heavy-duty ratings The ATV6A0C40N6 is a modular cabinet-mount AC drive from the Altivar Process ATV600 series, rated 280 kW at 500 V in normal duty and 220 kW at 500 V in heavy duty. The normal-duty line current is 380 A at 500 V; heavy-duty line current is 303 A at 500 V. Apparent power is 329 kVA at 500 V normal duty, 262 kVA at 500 V heavy duty. These are the numbers that govern transformer sizing, cable cross-section, and upstream breaker coordination — the heavy-duty figure is the one that holds the unit on the grid under a sustained overload. Switching frequency is adjustable from 2 to 4.9 kHz with a derating factor — raising it quiets the motor whine but reduces the continuous output current. The drive is designed for both asynchronous and synchronous motors, with braking to standstill by DC injection. ## STO SIL 3 and integrated protection suite The drive also provides thermal protection for both motor and drive, motor phase break detection, overcurrent between output phases and earth, short-circuit protection, overvoltages on the DC bus, line supply over/undervoltage, phase loss, and overspeed protection. That list covers the fault conditions a site electrical engineer needs to map into the protection logic without adding external relays. The integrated EMC filter is rated for 300 m cable at category C3 per IEC 61800-3 — suitable for industrial environments with a dedicated transformer, not for residential or public low-voltage networks. The prospective line short-circuit current is 50 kA, so the upstream protective device must be coordinated to that SCCR level. ## Modular construction and fieldbus flexibility This is the modular version — the kit ships as a control unit, mechanical mounting kits, power connection set of fuses, one 200 kW power module, and a front cover. Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy-chain RJ45, SUB-D 9, or screw terminals). Slot A/slot B also accept digital/analog I/O extension and output relay extension modules. The base drive includes a 2-wire RS 485 Modbus serial port with RTU frame, configurable 8-bit data, odd/even/no parity, and addresses 1–247. The Ethernet port runs Modbus TCP at 10/100 Mbit/s with half/full duplex autonegotiation. ## Cabinet integration and environmental ratings Cabinet-mount only — UL type 1 and UL type 12 per UL 61800-5-1 when integrated into a suitable enclosure. Pollution degree 2 per IEC 61800-5-1 (non-conductive pollution only). Operating altitude is below 2000 m with current derating above 1000 m. Vibration resistance is 1.5 mm peak-to-peak at 2–13 Hz and 0.5 gn at 13–200 Hz per IEC 60068-2-6; shock resistance is 4 gn for 11 ms per IEC 60068-2-27. Relative humidity range is 5–95% without condensation per IEC 60068-2-3. Noise level is 70 dB per 86/188/EEC.","metaTitle":"Schneider ATV6A0C40N6 Altivar Process VFD, 280 kW, 500 V","metaDescription":"Schneider Electric ATV6A0C40N6 Altivar Process ATV600 AC drive, 280 kW at 500 V normal duty, 220 kW heavy duty.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"380.0 A 500 V normal duty) 303.0 A 500 V heavy duty)","Frequency":"50...60 Hz - 5...5 %","Product Status":"Active","Pollution Degree":"Pollution degree 2","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.1 °C","Temperature Storage":"-40...158 °F (-40...70 °C)","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV6A0C40N6/variable-speed-drive-altivar-process-atv600-apm-single-500-v-280-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C40N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C40N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C40N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}