{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C45T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C45T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C45T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C45T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 modular drive, ATV6A0C45T4, 650 hp normal duty at 480 V, with STO SIL3 and integrated C3 EMC filter.","salesMarkdown":"The Schneider Electric ATV6A0C45T4 is a modular Altivar Process ATV600 variable speed drive rated for 650 hp normal duty and 550 hp heavy duty at 480 V, drawing 685 A normal duty line current. It holds strip tension under the radiant heat of a hot-strip mill because it pairs forced convection cooling with an integrated EMC filter rated for 300 m cable at IEC 61800-3 category C3, keeping drive EMI off the mill control network. The normal-duty / heavy-duty split dictates the operating margin for continuous process vs. overload cycles. At 480 V, heavy duty gives you 586 A and 355 kW for constant-torque loads like a conveyor or mill table; normal duty gives 685 A and 450 kW for variable-torque pumps or fans. The integrated STO function is rated SIL 3 per IEC 61508 and IEC 13849-1, so it can serve as the single-channel safety isolation on the motor without an external safety relay — provided the 24 V DC supply to the STO inputs stays within 21…27 V and is short-circuit protected. The control supply architecture needs a separate 24 V DC source for the digital inputs (19…30 V) and a regulated 10.5 V DC for a reference potentiometer (1 to 10 kOhm). The internal supply for digital inputs and STO is a separate 24 V DC rail with <200 mA overload and short-circuit protection, which means a fault on an input won't drop the STO line. Accuracy across three analog inputs stays within ±0.6 % over a 60 °C temperature swing, and ±0.15 % linearity error on the maximum value — enough to hold repeatable tension reference without recalibrating between shifts. Cabinet-mount, forced convection cooling. Pollution degree 2 per IEC 61800-5-1 (non-conductive dust, occasional condensation). Operating altitude: 1000 m base, derate 1 % per 100 m up to 4800 m. Shock resistance 7 gn at 11 ms — survives the mechanical bumps of a mill floor. Three configurable relay outputs (1 NO/NC fault relay, 2 NO sequence relays) rated for 100,000 cycles, enough for decades of fault signaling in a 20-year plant life. Option card slots A and B accept communication modules (Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen) and I/O extension modules. The embedded Ethernet/Modbus TCP port runs at 10/100 Mbit/s, half/full duplex with autonegotiation. A separate RS-485 serial port at 4.8 to 38.4 kbit/s uses RTU frames for legacy Modbus daisy chains.","metaTitle":"Schneider ATV6A0C45T4 ATV600, 650 HP Normal Duty","metaDescription":"Current-production ATV6A0C45T4, 650 hp normal duty at 480 V, STO SIL3, EMC filter C3, forced convection cooling. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6A0C45T4","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection","Marking":"CE","Variant":"Modular version","Accuracy":"+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"71 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 480 V, 650 hp","Line current":"685.0 A 480 V normal duty) 586.0 A 480 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Refresh time":"Relay output R1, R2, R3)5 ms +/- 0.5 ms)","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"569 kVA at 480 V normal duty 487 kVA at 480 V heavy duty","Motor power hp":"650.0 hp at 480 V normal duty 550.0 hp at 480 V heavy duty","Motor power kW":"450.0 kW at 480 V normal duty 355.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 3 power module 160 kW 2 front cover","Linearity error":"AI1, AI2, AI3 +/- 0.15 % of maximum value analog input AO1, AO2 +/- 0.2 % analog output","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Local signalling":"3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"7 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC 100000 cycles Configurable relay logic R2 sequence relay NO 100000 cycles Configurable relay logic R3 sequence relay NO 100000 cycles","Sampling duration":"2 ms +/- 0.5 ms DI1...DI4) - discrete input 5 ms +/- 1 ms DI5, DI6) - discrete input 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input 10 ms +/- 1 ms AO1) - analog output","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Analogue input type":"AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits","Discrete input type":"DI1...DI6 programmable, 24 V DC DI5, DI6 programmable as pulse input 0...30 kHz, 24 V DC STOA, STOB safe torque off, 24 V DC 2.2 kOhm","Input compatibility":"DI1...DI6 discrete input level 1 PLC IEC 61131-2 DI5, DI6 discrete input level 1 PLC IEC 65A-68 STOA, STOB discrete input level 1 PLC IEC 61131-2","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Analogue output type":"Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits Software-configurable current AO1, AO2 0...20 mA 10 bits","Discrete input logic":"Positive logic (source) DI1...DI6), < 5 V, > 11 V Negative logic (sink) DI1...DI6), > 16 V, < 10 V Positive logic (source) DI5, DI6), < 0.6 V, > 2.5 V Positive logic (source) STOA, STOB), < 5 V, > 11 V","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 11930 W 2.5 kHz normal duty) Forced convection 8960 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"830.0 A at 2.5 kHz normal duty 660.0 A at 2.5 kHz heavy duty","Maximum switching current":"Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC","Maximum transient current":"913 A 60 s normal duty) 990 A 60 s heavy duty)","Minimum switching current":"Relay output R1, R2, R3 5 mA 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6A0C45T4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6A0C45T4.pdf', 'path_name': 'c853be05e430518075893de4f9d73f71.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/c853be05e430518075893de4f9d73f71.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6A0C45T4/variable-speed-drive-altivar-process-atv600-apm-single-480-v-650-hp/"},"ai":{"faq":[{"question":"What are the key ratings of the ATV6A0C45T4?","answer":"Motor power: 650 hp normal duty, 550 hp heavy duty at 480 V. Line current: 685 A normal duty, 586 A heavy duty. Apparent power: 569 kVA normal, 487 kVA heavy. Integrated STO SIL3, EMC filter IEC 61800-3 category C3, forced convection cooling."},{"question":"What compliance documentation is available for the ATV6A0C45T4?","answer":"The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The evidence does not list additional RoHS or UL certifications, but CE and the listed IEC standards cover most industrial installations."},{"question":"What are the supply requirements for the control inputs?","answer":"Digital inputs require an external 24 V DC supply (19…30 V). The internal supply for digital inputs and STO is 24 V DC (21…27 V) with <200 mA overload and short-circuit protection. There is a separate 10.5 V DC supply for a reference potentiometer (1 to 10 kOhm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C45T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C45T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}