{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C63T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C63T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C63T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C63T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, ATV6A0C63T6, modular variable speed drive, 650 hp at 600 V normal duty, 550 hp heavy duty, IP20/UL Type 1, integrated EMC filter C3.","salesMarkdown":"The Schneider ATV6A0C63T6 is an Altivar Process ATV600 modular drive sized for 650 hp at 600 V normal duty or 550 hp at 600 V heavy duty, with corresponding line currents of 544 A and 464 A. It handles both synchronous and asynchronous motors, so you can standardize on one drive type across a mixed motor fleet. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs, which covers most industrial panel-to-motor distances without an external filter. Switching frequency is adjustable from 2 to 4.9 kHz with derating; if you need to run a long motor cable or reduce audible noise, account for the current derate at the higher end. The drive includes STO (Safe Torque Off) rated SIL 3, which removes the need for a separate safety relay on many Category 3 / PL d stop circuits. Thermal protection, motor phase loss, overcurrent, and DC bus overvoltage are all handled onboard — the protection list covers the failure modes that typically take out a drive in the first year. Pollution degree 2 (IEC 61800-5-1) means it's rated for a normal factory environment; if your panel sees conductive dust or condensation, you'll need to cabinet-mount it with a higher IP enclosure. ## Integration notes Cabinet-mount only — UL Type 1 and Type 12 with cabinet integration. The kit includes the power module, control unit, mechanical mounting kit, power connection set, and a set of fuses. Forced-convection cooling means you need clearance around the heatsink; follow the mounting guide for minimum free space above and below. Altitude derating starts above 1000 m — at 2000 m expect a current reduction, so size the drive for the derated figure if your installation is at elevation. Communication options are flexible: the drive ships with a Modbus serial port (RS-485, RTU, up to 38.4 kbps) and a Modbus TCP Ethernet port (10/100 Mbit, half/full duplex). Slot A accepts a Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen module; slot A/B also takes digital/analog I/O or relay extension cards. If you're integrating into a PROFINET or EtherNet/IP plant, budget for the option card — it's not included in the base unit.","metaTitle":"Schneider ATV6A0C63T6 Altivar Process ATV600, 650 HP","metaDescription":"Schneider ATV6A0C63T6 Altivar Process ATV600 drive, 650 HP at 600 V normal duty, 550 HP heavy duty. Active production, sourced to order. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6A0C63T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"71 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 600 V, 650 hp","Line current":"544.0 A 600 V normal duty) 464.0 A 600 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"565 kVA at 600 V normal duty 482 kVA at 600 V heavy duty","Motor power hp":"650.0 hp at 600 V normal duty 550.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 3.0 power module 200 kW 2 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 11520 W 2.5 kHz normal duty) Forced convection 8960 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"650.0 A at 2.5 kHz normal duty 520.0 A at 2.5 kHz heavy duty","Maximum transient current":"715 A 60 s normal duty) 780 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV6A0C63T6/variable-speed-drive-altivar-process-atv600-apm-single-600-v-650-hp/"},"ai":{"faq":[{"question":"What motors does the ATV6A0C63T6 support?","answer":"It drives both synchronous and asynchronous motors, so you can use it with induction motors or permanent-magnet synchronous motors without changing drive platforms."},{"question":"What safety functions are built in?","answer":"Safe Torque Off (STO) rated SIL 3 is integrated, meeting IEC 61508 and IEC 13849-1. No external safety relay is needed for a Category 3 stop."},{"question":"What is the maximum fault current the drive can handle?","answer":"The prospective line Isc is rated at 50 kA, so it can be installed on a supply with up to 50 kA fault current without additional series reactors, provided the upstream breaker coordinates."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C63T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C63T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}