{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C71Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C71Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C71Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C71Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular drive, ATV6A0C71Q4, 710 kW normal duty / 560 kW heavy duty at 400 V, 1192 A line current, with integrated EMC filter, STO SIL3.","salesMarkdown":"The ATV6A0C71Q4: Sized for a 710 kW induction motor on 400 V three-phase under normal duty; the heavy-duty rating steps down to 560 kW. Line current of 1192 A ND or 951 A HD sets the upstream breaker and cable class. Internal supply for digital inputs and STO is 24 V DC (21...27 V) at under 200 mA with overload protection; an external 24 V DC (19...30 V) supply feeds the discrete inputs if the internal rail is not used. The integrated EMC filter meets IEC 61800-3 Category C3 for up to 300 m of motor cable, which keeps the cabinet clean on most standard installations. Safe torque off (STO) functional safety is built in at SIL 3 per IEC 61508 – no separate safety module needed for the stop circuit on machinery that requires it. Cabinet-mounted, forced convection cooled. Pollution degree 2 per IEC 61800-5-1. Shock resistance rated at 7 gn for 11 ms. Relative humidity 5 to 95 % non-condensing. Ambient temperature range is not explicitly listed, but the storage and handling limits are typically wider than operating range – the integrated fan and heatsink assume a clean airflow path.","metaTitle":"Schneider ATV6A0C71Q4 Altivar Process Drive, 710 kW","metaDescription":"Active ATV600 drive, 710 kW ND / 560 kW HD, 1192 A line current, integrated EMC filter C3, STO SIL3. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6A0C71Q4","Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection","Marking":"CE","Variant":"Modular version","Accuracy":"+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"74 dB conforming to 86/188/EEC","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 400 V, 710 kW","Line current":"1192.0 A at 400 V (normal duty) 951.0 A at 400 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Refresh time":"Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"826 kVA at 400 V normal duty 659 kVA at 400 V heavy duty","Motor power kW":"710.0 kW at 400 V normal duty 560.0 kW at 400 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 5 power module 160 kW 4 front cover","Linearity error":"AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output","Protection type":"Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Local signalling":"3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"7 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles","Sampling duration":"2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Analogue input type":"AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits","Discrete input type":"DI1...DI6 programmable, 24 V DC ( DI5, DI6 programmable as pulse input: 0...30 kHz, 24 V DC ( STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Input compatibility":"DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2","Number of addresses":"1...247 for Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Analogue output type":"Software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits","Discrete input logic":"Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars","Power dissipation in W":"Forced convection: 18290 W, switching frequency 2.5 kHz (normal duty) Forced convection: 13570 W, switching frequency 2.5 kHz (heavy duty)","IP degree of protection":"IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"1260.0 A at 2.5 kHz normal duty 1020.0 A at 2.5 kHz heavy duty","Maximum switching current":"Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC","Maximum transient current":"1386 A during 60 s (normal duty) 1530 A during 60 s (heavy duty)","Minimum switching current":"Relay output R1, R2, R3: 5 mA at 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"400 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/za/en/product/download-pdf/ATV6A0C71Q4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6A0C71Q4.pdf', 'path_name': '2e64b394486604a236df4d47faf59388.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/2e64b394486604a236df4d47faf59388.pdf', 'status': 1}","sourceUrl":"https://www.se.com/za/en/product/ATV6A0C71Q4/variable-speed-drive-altivar-process-atv600-apm-single-400-v-710-kw/"},"ai":{"faq":[{"question":"What is the supply requirement for digital inputs and STO?","answer":"The drive provides an internal 24 V DC supply (21...27 V) for digital inputs and safe torque off, rated at under 200 mA with overload and short-circuit protection. An external 24 V DC supply (19...30 V) can also be used for the digital inputs."},{"question":"What compliance markings does this drive carry?","answer":"It carries CE marking and conforms to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1."},{"question":"What is the motor power rating at 400 V?","answer":"710 kW for normal duty and 560 kW for heavy duty at 400 V, with corresponding line currents of 1192 A and 951 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C71Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C71Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}