{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C80T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C80T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C80T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C80T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV6A0C80T6, 800 hp at 600 V normal duty, STO SIL3, integrated C3 EMC filter, cabinet mount, forced convection cooling.","salesMarkdown":"The Schneider ATV6A0C80T6 is a modular Altivar Process drive rated for 800 hp at 600 V normal duty, 650 hp heavy duty, with Safe Torque Off SIL 3 that meets IEC 61508. The integrated C3 EMC filter handles motor cable runs up to 300 m without an external filter — a real money saver in retrofits. It shrugs off the vibration (0.5 gn at 13–200 Hz) and shock (4 gn, 11 ms), so it survives the crusher floor. Line current: 670 A normal duty, 547 A heavy duty at 600 V. THDI stays below 48% at full load per IEC 61000-3-12. Apparent power 696 kVA normal, 568 kVA heavy. ## Integration & wiring notes Cabinet mount with forced convection cooling. Line side uses M10 x 2 bars; control wiring fits removable screw terminals 0.5–1.5 mm². Pollution degree 2 per IEC 61800-5-1. Switching frequency adjustable 2–4.9 kHz with derating, and operating altitude up to 2000 m with derating above 1000 m. Communication slot A fieldbus options include Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen. Modbus serial on 2-wire RS-485 at 4.8–38.4 kbps, RTU format, addresses 1–247. Ethernet at 10/100 Mbit/s with auto-negotiation. Standard set includes a power module, control unit, mechanical mounting kits, power connection set of fuses, and front cover. The kit composition is ready for panel integration.","metaTitle":"Schneider ATV6A0C80T6 Altivar Process 800 hp Drive, STO SIL3","metaDescription":"Schneider ATV6A0C80T6 VFD, 800 hp at 600V, STO SIL3, C3 EMC filter. Active production, quoted to order. Built for mining vibration and shock. CE marked, modular.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6A0C80T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 600 V, 800 hp","Line current":"670.0 A 600 V normal duty) 547.0 A 600 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"696 kVA at 600 V normal duty 568 kVA at 600 V heavy duty","Motor power hp":"800.0 hp at 600 V normal duty 650.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 4.0 power module 200 kW 3 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 14200 W 2.5 kHz normal duty) Forced convection 11520 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"830.0 A at 2.5 kHz normal duty 650.0 A at 2.5 kHz heavy duty","Maximum transient current":"913 A 60 s normal duty) 975 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/ATV6A0C80T6/variable-speed-drive-altivar-process-atv600-apm-single-600-v-800-hp/"},"ai":{"faq":[{"question":"What is the marking and variant for this drive?","answer":"The marking is CE, and the variant is the Modular version (power module plus control unit)."},{"question":"What compliance documentation is available for the ATV6A0C80T6?","answer":"The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. CE marking applies."},{"question":"What are the key ratings for the ATV6A0C80T6?","answer":"Motor power: 800 hp normal duty, 650 hp heavy duty at 600 V. Line current: 670 A normal, 547 A heavy. Integrates a C3 EMC filter for 300 m cable runs. Safe Torque Off SIL 3. Shock 4 gn, vibration 0.5 gn."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C80T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C80T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}