{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0M10Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0M10Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0M10Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0M10Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular variable speed drive, ATV6A0M10Q4, 1000 kW at 400 V normal duty, 800 kW heavy duty, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The Schneider ATV6A0M10Q4 is an Altivar Process ATV600 drive rated for 1000 kW at 400 V normal duty and 800 kW heavy duty. It's a modular cabinet-mount unit with an integrated EMC filter compliant to IEC 61800-3 category C3 for 300 m cable runs, and STO SIL 3 safety function on board. The lifecycle status is current, so this is a live BOM line, not a last-time-buy scavenge. Line current at 400 V is 1542 A normal duty, 1246 A heavy duty — this drives your cable sizing and upstream breaker coordination. Apparent power works out to 1175 kVA normal, 950 kVA heavy, so the drive's input transformer or generator must be sized accordingly. The integrated EMC filter is rated for 300 m of motor cable under category C3 (industrial environment, not residential). If your installation requires longer cable runs or a lower conducted emission limit (C2), you'll need an external output filter. The drive also carries STO SIL 3 per IEC 61508 / IEC 13849-1, which means it can be wired directly into a safety circuit without a separate safety relay for the torque-off function. ## Supply and control wiring Digital inputs need an external 24 V DC supply (19...30 V). The drive provides an internal 10.5 V DC reference for a 1 to 10 kOhm potentiometer, and a separate 24 V DC supply (21...27 V) for digital inputs and STO, rated <200 mA with overload and short-circuit protection. That means you can power the control logic from the drive itself for small panels, but for larger systems with many I/O points, a dedicated 24 V DC supply is still recommended to stay within the 200 mA budget. Analog inputs (AI1, AI2, AI3) are software-configurable for voltage (0...10 V DC, 30 kOhm) or current (0...20 mA / 4...20 mA, 250 Ohm), 12-bit resolution. Accuracy is ±0.6 % over a 60 °C temperature variation. ## Communication and expansion Embedded Modbus serial (2-wire RS-485, RTU frame) and Modbus TCP (Ethernet, 10/100 Mbit/s, half/full duplex with autonegotiation) are standard. Slot A accepts fieldbus option modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). Slots A and B also accept digital/analog I/O extension or output relay extension modules. If you need a second fieldbus or extra I/O, this drive can take it without a separate gateway.","metaTitle":"Schneider ATV6A0M10Q4 Altivar Process ATV600, 1000 kW normal","metaDescription":"Schneider ATV6A0M10Q4 Altivar Process ATV600 drive, 1000 kW at 400 V normal duty, 800 kW heavy duty. Integrated EMC filter C3, STO SIL 3. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection","Marking":"CE","Variant":"Modular version","Accuracy":"+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"75 dB conforming to 86/188/EEC","Line current":"1542.0 A at 400 V (normal duty) 1246.0 A at 400 V (heavy duty)","Maximum THDI":"<48 % full load","Refresh time":"Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Option Module":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Apparent power":"1175 kVA at 400 V normal duty 950 kVA at 400 V heavy duty","Motor power kW":"1000.0 kW at 400 V normal duty 800.0 kW at 400 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 6 power module 160 kW 5 front cover","Linearity error":"AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output","Protection type":"Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Local signalling":"3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles","Sampling duration":"2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"0...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Analogue input type":"AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits","Discrete input type":"DI1...DI6 programmable, 24 V DC ( DI5, DI6 programmable as pulse input: 0...30 kHz, 24 V DC ( STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Input compatibility":"DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2","Number of addresses":"1...247 for Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Analogue output type":"Software-configurable voltage AO1, AO2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AO1, AO2: 0...20 mA, resolution 10 bits","Discrete input logic":"Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars","Power dissipation in W":"Forced convection: 29940 W, switching frequency 2.5 kHz (normal duty) Forced convection: 20700 W, switching frequency 2.5 kHz (heavy duty)","IP degree of protection":"IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"1770.0 A at 2.5 kHz normal duty 1420.0 A at 2.5 kHz heavy duty","Maximum switching current":"Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC","Maximum transient current":"1947 A during 60 s (normal duty) 2130 A during 60 s (heavy duty)","Minimum switching current":"Relay output R1, R2, R3: 5 mA at 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"400 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6A0M10Q4/variable-speed-drive-altivar-process-atv600-apm-single-400v-1000kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6A0M10Q4/alternatives.json"},"ai":{"faq":[{"question":"What are the motor power ratings for this drive?","answer":"1000 kW at 400 V normal duty and 800 kW at 400 V heavy duty."},{"question":"What safety function does the ATV6A0M10Q4 support?","answer":"Safe Torque Off (STO) rated SIL 3 per IEC 61508 and IEC 13849-1."},{"question":"What EMC filter is integrated?","answer":"An integrated EMC filter compliant to IEC 61800-3 category C3, rated for 300 m of motor cable."},{"question":"What supply voltages does the control section need?","answer":"Digital inputs require an external 24 V DC (19...30 V). The drive provides an internal 10.5 V DC reference for a potentiometer and a separate 24 V DC (21...27 V) supply for digital inputs and STO, rated <200 mA with overload and short-circuit protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0M10Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0M10Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}