{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C11T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C11T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C11T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C11T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular drive ATV6B0C11T6, 125 hp normal duty at 600 V, 102 A line current, integrated EMC filter, active production.","salesMarkdown":"## Drive selection memo — ATV6B0C11T6 This Altivar Process ATV600 drive is sized for a 125 hp induction motor at 600 V normal duty, pulling 102 A line current. Under heavy duty it still delivers 100 hp with 82 A, so it holds up to the steam of a tire curing press where the load profile may demand a safety margin on current. Built as a modular version, it accepts slot A and B option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen — the communication layer you need to nail the cure recipe across the line. The integrated EMC filter provides C3 category suppression per IEC 61800-3 for 300 m cable runs; standard compliance includes IEC 61800-5-1, UL 61800-5-1, and functional safety STO SIL3 per IEC 61508. Forced convection cooling and a 5–95% humidity range without condensation make it rated for press temperatures and steam-laden plant air — just keep the cabinet vent clear. ## Cabinet integration checklist Mounting: cabinet mount, UL Type 1 or Type 12 (conforming to UL 61800-5-1). Forced convection requires minimum clearances around the module — refer to the mechanical dimensions from the mounting kit. Electrical connection: line side via screw terminals; motor side via M10 x 2 bars. Control wiring: removable screw terminals accepting 0.5–1.5 mm² / AWG 20–16. Option cards plug into slots A and B; slot A also accepts communication modules, slot A/slot B accept I/O or relay extension. Communication: Modbus serial via 2-wire RS485 at 4.8–38.4 kbit/s RTU, plus Ethernet IP/Modbus TCP at 10/100 Mbit/s autonegotiation. Adjustable switching frequency from 2 to 4.9 kHz; derate above 1000 m altitude.","metaTitle":"Schneider ATV6B0C11T6 Altivar Process ATV600 Drive, 125 hp","metaDescription":"Active-production modular drive rated 125 hp at 600 V normal duty, 102 A line current, integrated C3 EMC filter, STO SIL3. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C11T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 600 V, 125 hp","Line current":"102.0 A 600 V normal duty) 82.0 A 600 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"106 kVA at 600 V normal duty 86 kVA at 600 V heavy duty","Motor power hp":"125.0 hp at 600 V normal duty 100.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 4090 W 2.5 kHz normal duty) Forced convection 3250 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"125.0 A at 2.5 kHz normal duty 105.0 A at 2.5 kHz heavy duty","Maximum transient current":"137.5 A 60 s normal duty) 157.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV6B0C11T6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-600-v-125-hp/"},"ai":{"faq":[{"question":"What compliance documentation does this drive provide?","answer":"It is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. Functional safety includes STO SIL3. RoHS/REACH declarations are available from Schneider on request."},{"question":"What are the key electrical ratings?","answer":"Normal duty: 125 hp at 600 V, 102 A line current, 106 kVA apparent power. Heavy duty: 100 hp at 600 V, 82 A line current, 86 kVA. Output voltage equals supply voltage. The drive can handle synchronous and asynchronous motors."},{"question":"What fieldbus options are available?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen modules. Slots A or B accept digital/analog I/O extension or output relay extension. Built-in Modbus serial (RS485) and Ethernet IP/Modbus TCP are standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C11T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C11T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}