{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C13N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C13N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C13N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C13N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, 90 kW/75 kW at 500 V, modular version, integrated EMC filter category C3.","salesMarkdown":"The Schneider ATV6B0C13N6 is a current-production modular Altivar Process ATV600 drive built for asynchronous and synchronous motors. It's the variant you spec when you need 90 kW normal duty (75 kW heavy duty) at 500 V three-phase — that's the line current of 117 A normal, 98 A heavy duty right there in the catalog. It's listed as a modular version, which means the power section and control unit ship separately — you get the control module, mounting kits, power connection set, and fuses in one box. That matters when you're panel building because you don't have to pull the whole drive to swap a control board. The integrated EMC filter is rated for 984.3 ft (300 m) motor cable with category C3 per IEC 61800-3. That's enough for most industrial runs without an add-on filter. If your site has a dedicated transformer or you're in a data center hyperscale hall, you might still need an external C2 filter — but for a typical plant floor, this filter saves you a line item. For the controls integrator: the onboard Modbus serial is 8-bit RTU with configurable parity, addressing 1 to 247. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen in various physical forms. If you're tying this into a Rockwell or Siemens backbone, pick the right option card and be done. The STO safety function carries SIL3 — that's a hard requirement on some CE-marked machinery. It kills torque without dropping the main power contactor, so you can clear a jam without cycling the whole line. Switching frequency is adjustable from 2 to 4.9 kHz with derating. For a 90 kW motor you'll likely park it at 2 kHz to keep the drive cool — forced convection fans are built in, but higher frequencies push more heat into the cabinet. Vibration resistance: 1.5 mm peak-to-peak 2–13 Hz, 0.5 gn 13–200 Hz. It'll take the shake near a compressor skid, but I've buried plenty of smaller drives on poorly isolated pump bases — this one is tougher, but bolt it to a stiff panel to trust that spec.","metaTitle":"Schneider ATV6B0C13N6 Altivar Process ATV600, 90kW","metaDescription":"Current-production ATV600 modular drive; 90kW normal duty/75kW heavy duty at 500V, integrated EMC filter C3, STO SIL3. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV6B0C13N6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 500 V, 90 kW","Line current":"117.0 A 500 V normal duty) 98.0 A 500 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"101 kVA at 500 V normal duty 85 kVA at 500 V heavy duty","Motor power kW":"90.0 kW at 500 V normal duty 75.0 kW at 500 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 4530 W 2.5 kHz normal duty) Forced convection 3890 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty","Maximum transient current":"159.5 A 60 s normal duty) 187.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV6B0C13N6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-500-v-90-kw/"},"ai":{"faq":[{"question":"What is the variant listed for this part?","answer":"It is the modular version, meaning the control unit and power section are separate components shipped together. This allows easier service and replacement of individual modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C13N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C13N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}