{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C13Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C13Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C13Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C13Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular VFD, ATV6B0C13Q4, 132 kW normal duty / 110 kW heavy duty at 400 V, 208 A line current, STO SIL 3, integrated EMC C3 filter.","salesMarkdown":"## Drive selection memo — ATV6B0C13Q4 Schneider's ATV6B0C13Q4 is a modular Altivar Process ATV600 drive rated for 132 kW normal duty and 110 kW heavy duty at 400 V, drawing 208 A line current in normal duty and 174 A in heavy duty. It ships as a kit: power module, control unit, mounting hardware, power connection set, and a set of fuses — no separate ordering of accessories for a basic install. Built for both asynchronous and synchronous motors, with an adjustable switching frequency from 2 to 8 kHz (derate above 2.5 kHz). The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs, so you can skip an external filter for most industrial line-ups. Pollution degree 2, vibration and shock per IEC 60068-2-6 and 60068-2-27. ## Fieldbus and I/O — slot architecture Slot A accepts a communication module for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). Slot A and slot B can each take a digital/analog I/O extension or an output relay extension. The base unit includes a slave Modbus TCP port (10/100 Mbit/s) and a 2-wire RS 485 Modbus serial port (4.8 to 38.4 kbit/s, RTU frame, 1–247 addresses). Control wiring lands on removable screw terminals accepting 0.5–1.5 mm² (AWG 20–16). Line-side connection is screw terminal; motor connection uses M10 x 2 bars. This is a current-production item — no end-of-life notice on file. It carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter is C3 rated for 300 m cable, and total harmonic current distortion (THDI) stays under 5% at full load per IEEE 519. Operating altitude is 1000 m base with derating up to 4800 m. Ambient relative humidity 5–95% non-condensing. Power dissipation at 2.5 kHz switching: 5040 W normal duty, 4180 W heavy duty — plan cabinet cooling accordingly.","metaTitle":"Schneider ATV6B0C13Q4 Altivar Process ATV600, 132 kW normal","metaDescription":"Schneider ATV6B0C13Q4 Altivar Process ATV600 drive, 132 kW / 110 kW heavy duty, 208 A line current, STO SIL 3, integrated EMC C3 filter. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0C13Q4","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"70 dB conforming to 86/188/EEC","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","description":"variable speed drive APM, ATV600, Low Harmonic drive, 400 V, 132 kW","Line current":"208.0 A at 400 V (normal duty) 174.0 A at 400 V (heavy duty)","Maximum THDI":"<5 % full load conforming to IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"144 kVA at 400 V normal duty 121 kVA at 400 V heavy duty","Motor power kW":"132.0 kW at 400 V normal duty 110.0 kW at 400 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 160 kW 1.0 front cover","Protection type":"Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"1000...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Number of addresses":"1...247 for Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars","Power dissipation in W":"Forced convection: 5040 W, switching frequency 2.5 kHz (normal duty) Forced convection: 4180 W, switching frequency 2.5 kHz (heavy duty)","IP degree of protection":"IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Network number of phases":"3 phases","Continuous output current":"250.0 A at 2.5 kHz normal duty 211.0 A at 2.5 kHz heavy duty","Maximum transient current":"275 A during 60 s (normal duty) 316.5 A during 60 s (heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"400 V - 15...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C13Q4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C13Q4.pdf', 'path_name': 'e53588c46677eec58671e82e259c4f52.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/e53588c46677eec58671e82e259c4f52.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C13Q4/variable-speed-drive-apm-atv600-low-harmonic-drive-400-v-132-kw/"},"ai":{"faq":[{"question":"What are the key ratings for ATV6B0C13Q4?","answer":"132 kW normal duty / 110 kW heavy duty at 400 V, 208 A line current normal duty, 174 A heavy duty, STO SIL 3 safety function, integrated EMC C3 filter for 300 m cable."},{"question":"What fieldbus options does this drive support?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen modules. Base unit includes slave Modbus TCP and RS 485 Modbus serial."},{"question":"What compliance documentation is available?","answer":"CE marking, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and IEEE 519 for THDI <5%."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C13Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C13Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}