{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C13Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C13Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C13Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C13Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular version, ATV6B0C13Q6, 132 kW at 690 V normal duty, 110 kW heavy duty, integrated EMC filter C3.","salesMarkdown":"The Schneider ATV6B0C13Q6 is an Altivar Process ATV600 drive in the modular version, rated 132 kW at 690 V normal duty and 110 kW at 690 V heavy duty. It handles synchronous and asynchronous motors, with line current of 122 A normal duty, 102 A heavy duty at 690 V. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs, and the drive carries STO (safe torque off) SIL 3. The 132 kW normal-duty / 110 kW heavy-duty split is the key selection gate: normal duty covers constant-torque loads like conveyors; heavy duty applies to variable-torque pumps and fans where peak current is lower. The drive's apparent power is 146 kVA normal duty, 122 kVA heavy duty at 690 V. Switching frequency is adjustable from 2 to 4.9 kHz with derating — higher frequencies reduce motor noise but increase thermal load on the drive. Forced convection cooling means the drive needs clearance around the heatsink; cabinet integration requires UL type 1 or type 12 enclosure integration per UL 61800-5-1. Operating altitude is below 2000 m with current derating above 1000 m. The drive includes a full set of protection functions: thermal protection for drive and motor, safe torque off, overcurrent, short-circuit, phase loss, overvoltage/undervoltage on the DC bus, overspeed, and motor phase break. Prospective line Isc is 50 kA, so the drive can be installed on high-fault-capacity supplies without additional series fusing in most cases. The kit composition includes the power module, control unit, mechanical mounting kit, and a power connection set of fuses — a near-complete package for installation. ## Fieldbus and I/O options The drive ships with Modbus serial (2-wire RS-485, RTU frame, 1–247 addresses) and Modbus TCP slave access on a 10/100 Mbit/s Ethernet port. Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slot A/B also accept digital/analog I/O extension and output relay extension modules. This gives flexibility to match existing fieldbus architecture without a separate gateway.","metaTitle":"Schneider ATV6B0C13Q6 Altivar Process ATV600, 132 kW at 690","metaDescription":"Schneider ATV6B0C13Q6 Altivar Process ATV600 drive, 132 kW at 690 V normal duty. Active production. Integrated EMC filter C3. STO SIL 3. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C13Q6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 690 V, 132 kW","Line current":"122.0 A 690 V normal duty) 102.0 A 690 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"146 kVA at 690 V normal duty 122 kVA at 690 V heavy duty","Motor power kW":"132.0 kW at 690 V normal duty 110.0 kW at 690 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 5030 W 2.5 kHz normal duty) Forced convection 4290 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty","Maximum transient current":"159.5 A 60 s normal duty) 187.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6B0C13Q6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-690-v-132-kw/"},"ai":{"faq":[{"question":"What are the key motor power ratings for the ATV6B0C13Q6?","answer":"The drive is rated 132 kW at 690 V normal duty and 110 kW at 690 V heavy duty. Line current is 122 A normal duty and 102 A heavy duty at 690 V."},{"question":"What fieldbus options does the ATV6B0C13Q6 support?","answer":"It has built-in Modbus serial (RS-485, RTU) and Modbus TCP. Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen (three connector variants). Slot A/B also accept I/O extension and relay output modules."},{"question":"Does the ATV6B0C13Q6 include an EMC filter?","answer":"Yes, it has an integrated EMC filter rated for 300 m cable runs per IEC 61800-3 category C3."},{"question":"What safety functions does the ATV6B0C13Q6 provide?","answer":"It includes safe torque off (STO) rated SIL 3, along with thermal protection, overcurrent, short-circuit, phase loss, overvoltage/undervoltage, and overspeed protection for both drive and motor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C13Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C13Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}