{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C16N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C16N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C16N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C16N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, ATV6B0C16N6, modular drive, 110 kW at 500 V normal duty, line current 141 A, integrated EMC filter C3.","salesMarkdown":"## Drive overview The Schneider ATV6B0C16N6 is a modular Altivar Process ATV600 drive rated for 110 kW at 500 V normal duty, drawing 141 A line current at that condition. It handles both asynchronous and synchronous motors, with an adjustable switching frequency from 2 to 4.9 kHz. The integrated EMC filter meets category C3 per IEC 61800-3, good for up to 300 m of motor cable in typical industrial installations. The heavy-duty rating is 90 kW at 500 V with 117 A line current, so it carries the usual headroom for constant-torque loads or higher ambient conditions. ## Integration and communication The drive comes with a slot A for fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen (RJ45 or SUB-D 9 or screw terminals). The base unit includes Modbus serial (2-wire RS485, RTU, up to 38.4 kbit/s) and Modbus TCP (10/100 Mbit/s) as standard. That covers most line-side connections without an extra card. For I/O expansion, slot A or slot B accepts digital/analog I/O extension modules or relay output modules. Cabinet mount, forced convection cooling. Pollution degree 2. Vibration resistance per IEC 60068-2-6: 1.5 mm peak-to-peak from 2 to 13 Hz, 0.5 gn from 13 to 200 Hz. ## Safety and compliance Safe torque off (STO) built in, rated SIL 3. Thermal protection for both motor and drive, plus short-circuit, earth fault, overvoltage/undervoltage, phase loss, and overspeed protection. Marking CE; design meets IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Integrated EMC filter C3 keeps conducted emissions within limits for industrial second environment (not residential). No external filter needed for most installations.","metaTitle":"Schneider ATV6B0C16N6 Altivar Process ATV600, 110 kW","metaDescription":"ATV6B0C16N6 modular drive rated 110 kW at 500 V normal duty, 141 A line current, integrated EMC C3, STO SIL3. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV6B0C16N6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 500 V, 110 kW","Line current":"141.0 A 500 V normal duty) 117.0 A 500 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"122 kVA at 500 V normal duty 101 kVA at 500 V heavy duty","Motor power kW":"110.0 kW at 500 V normal duty 90.0 kW at 500 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 5470 W 2.5 kHz normal duty) Forced convection 4530 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty","Maximum transient current":"192.5 A 60 s normal duty) 217.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV6B0C16N6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-500-v-110-kw/"},"ai":{"faq":[{"question":"What compliance documentation comes with this drive?","answer":"The drive carries CE marking and is designed to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets C3. Documentation supporting those standards is available on request."},{"question":"What are the key electrical ratings?","answer":"Motor power: 110 kW normal duty / 90 kW heavy duty at 500 V. Line current: 141 A normal duty / 117 A heavy duty at 500 V. Apparent power: 122 kVA normal duty / 101 kVA heavy duty. Output voltage equals supply voltage. Line supply frequency 50/60 Hz ±5%."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C16N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C16N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}