{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C16Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C16Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C16Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C16Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV600, modular version, ATV6B0C16Q6, 160 kW at 690 V heavy duty, integrated EMC filter C3.","salesMarkdown":"The Schneider ATV6B0C16Q6 is a modular variable speed drive from the Altivar Process ATV600 series, sized for 160 kW at 690 V in heavy-duty motor duty and 122 A line current under the same condition — that's your load-fit anchor when commissioning a 690 V induction or synchronous motor. The integrated EMC filter meets IEC 61800-3 category C3 for industrial environments, so you can skip an external filter in most panel builds. Safe torque off (STO) at SIL 3 is built in, eliminating the need for a separate safety relay for that function. Cabinet-mount only, forced convection cooling — ensure clearance for airflow. Pollution degree 2 environment expected. Electrical connections: line side via screw terminals, motor side via M10 bus bars (torque to manufacturer spec). Slot A accepts communication option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D, or screw terminals); slot A/B can host digital/analog I/O or relay extension modules. Commissioning engineer tip: the switching frequency is adjustable from 2 to 4.9 kHz with a derating factor, and the integrated EMC filter covers up to 300 m of motor cable at C3 level.","metaTitle":"Schneider ATV6B0C16Q6 ATV600 Drive, 160kW 690V","metaDescription":"Schneider ATV6B0C16Q6 modular drive in current production, rated 160 kW at 690 V heavy duty, with integrated EMC filter and STO SIL3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C16Q6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 690 V, 160 kW","Line current":"148.0 A 690 V normal duty) 122.0 A 690 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"177 kVA at 690 V normal duty 146 kVA at 690 V heavy duty","Motor power kW":"160.0 kW at 690 V normal duty 132.0 kW at 690 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 6080 W 2.5 kHz normal duty) Forced convection 5030 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty","Maximum transient current":"192.5 A 60 s normal duty) 217.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C16Q6?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C16Q6.pdf', 'path_name': 'd0087743130985ee69e7d8243cdce252.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/d0087743130985ee69e7d8243cdce252.pdf', 'status': 1}","sourceUrl":"https://www.se.com/in/en/product/ATV6B0C16Q6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-690-v-160-kw/"},"ai":{"faq":[{"question":"What are its CE marking and key standards?","answer":"The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1."},{"question":"What is the maximum motor power at 690 V heavy duty?","answer":"Rated 132 kW heavy duty and 160 kW normal duty at 690 V, with corresponding line currents of 122 A and 148 A."},{"question":"Does it include safe torque off?","answer":"Yes, STO (safe torque off) at SIL 3 is integrated into the drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C16Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C16Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}