{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C16T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C16T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C16T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C16T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ATV6B0C16T6, Altivar Process ATV600 modular drive, 175 hp normal duty / 150 hp heavy duty at 600 V, integrated EMC filter C3, Safe Torque Off SIL3, current production.","salesMarkdown":"## Drive core with fieldbus flexibility The ATV6B0C16T6 is the main power-and-control assembly of the ATV600 line in a modular format. It delivers 175 hp at 600 V normal duty or 150 hp heavy duty, with a line current of 142 A normal / 121 A heavy. The drive is designed for asynchronous and synchronous motors. Slot A accepts any of the listed communication modules — Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen — so the network interface is chosen during integration, not baked in at order. The control unit and power module separate, making upgrades or field swaps simpler. Safety is covered on-board: Safe Torque Off (STO) to SIL 3 without an additional safety module. The integrated EMC filter (category C3) supports 300 m of motor cable, covering most industrial installations. ## Production status and modular sourcing The modular version means you can replace or upgrade the control unit or power module independently. If a later revision emerges mid-lifecycle, a full unit swap isn't forced — just the affected segment. ## Cabinet installation and integration notes Cabinet mount with forced convection cooling. Pollution degree 2 interior; UL type 1 or 12 as part of the cabinet integration. The kit includes one power module (200 kW), control unit, mechanical mounting kits, power connection set, and fuses — everything in one order code. For connection: line side screw terminal, motor M10 x 2 bars, control via removable screw terminals 0.5...1.5 mm². The switching frequency is adjustable from 2 to 4.9 kHz with derating. Default communication via Modbus serial (RS-485, 2-wire, RTU frame, up to 38.4 kbit/s) and Modbus TCP (10/100 Mbit/s, half/full duplex). The drive also carries multiple protections: thermal, short-circuit, overvoltage, undervoltage, phase loss, overspeed, and break on control circuit — all listed under protection type.","metaTitle":"Schneider Electric ATV6B0C16T6 Altivar Process ATV600, 175 h","metaDescription":"Current production. Schneider ATV6B0C16T6 ATV600 modular drive, 175 hp normal duty / 150 hp heavy duty at 600 V, integrated EMC filter C3, STO SIL3. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C16T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 600 V, 175 hp","Line current":"142.0 A 600 V normal duty) 121.0 A 600 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"147 kVA at 600 V normal duty 126 kVA at 600 V heavy duty","Motor power hp":"175.0 hp at 600 V normal duty 150.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 5770 W 2.5 kHz normal duty) Forced convection 4930 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty","Maximum transient current":"192.5 A 60 s normal duty) 217.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C16T6?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C16T6.pdf', 'path_name': 'b2c8ef7abdbcf4f091a4bad9aca9434e.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/b2c8ef7abdbcf4f091a4bad9aca9434e.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C16T6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-600-v-175-hp/"},"ai":{"faq":[{"question":"What is ATV6B0C16T6's listed variant?","answer":"The variant is Modular version, meaning the control unit and power module are separate assemblies that can be sourced or replaced individually."},{"question":"What is the CE marking on this drive?","answer":"The marking is CE as shown in the specifications."},{"question":"What compliance documentation does Schneider provide for ATV6B0C16T6?","answer":"The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C16T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C16T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}