{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C25N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C25N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C25N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C25N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV6B0C25N6 modular VFD, 160 kW normal duty / 132 kW heavy duty at 500 V, 204 A line current, STO SIL 3, integrated EMC filter C3, cabinet mount.","salesMarkdown":"## 160 kW at 500 V — normal and heavy duty ratings The ATV6B0C25N6 is a modular Altivar Process ATV600 drive rated 160 kW normal duty and 132 kW heavy duty at 500 V supply. The normal-duty figure governs continuous fan/pump loads; the heavy-duty figure applies to constant-torque applications like conveyors or extruders where the drive must deliver rated torque across the speed range. Line current at 500 V is 204 A normal duty, 169 A heavy duty — this sets the upstream breaker and cable sizing. Apparent power is 176 kVA normal duty, 146 kVA heavy duty, which feeds into transformer sizing and power factor correction planning. ## Safety and compliance — STO SIL 3, EMC, harmonic limits This simplifies the safety circuit design for guarding applications where the drive must remove torque on a safety demand. The integrated EMC filter meets IEC 61800-3 category C3 with 300 m motor cable — covers most industrial installations without an external filter. Total harmonic current distortion (THDI) is below 5% at full load per IEEE 519, so harmonic compliance is built in for typical plant distribution systems. Prospective line short-circuit current rating is 50 kA — the drive is rated for installation on supplies with up to 50 kA available fault current, which covers most industrial service entrances without additional current-limiting fusing upstream. ## Modular construction and fieldbus options This is the modular version — the power section and control section are separate assemblies. That means a control module swap or upgrade does not require removing the power wiring, and a power module replacement leaves the control wiring intact. The kit includes the control unit, power module, mounting kit, power connection set, fuses, and front cover. Slot A accepts communication option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). The base unit includes a 2-wire RS 485 Modbus serial port running RTU protocol at 4.8 to 38.4 kbit/s, plus a Modbus TCP/Ethernet IP port at 10/100 Mbit/s. ## Mounting, cooling, and environmental limits Cabinet mount only — UL type 1 or type 12 enclosure integration per UL 61800-5-1. Forced convection cooling with a noise level of 73 dB. Operating altitude is up to 2000 m with current derating above 1000 m; relative humidity 5-95% non-condensing per IEC 60068-2-3. Vibration resistance: 1.5 mm peak-to-peak at 2-13 Hz, 0.5 gn at 13-200 Hz per IEC 60068-2-6. Shock resistance: 4 gn for 11 ms per IEC 60068-2-27. Pollution degree 2 per IEC 61800-5-1 — suitable for typical control room or electrical room environments without conductive contamination.","metaTitle":"Schneider ATV6B0C25N6 Altivar Process Drive, 160 kW, 500 V","metaDescription":"Schneider Electric ATV6B0C25N6 Altivar Process ATV600 drive, 160 kW normal duty at 500 V, 204 A line current, STO SIL 3, integrated EMC filter C3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"204.0 A 500 V normal duty) 169.0 A 500 V heavy duty)","Frequency":"50...60 Hz - 5...5 %","Product Status":"Active","Pollution Degree":"Pollution degree 2","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.1 °C","Temperature Storage":"-40...158 °F (-40...70 °C)","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV6B0C25N6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-500-v-160-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C25N6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C25N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C25N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}