{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C25T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C25T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C25T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C25T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, ATV6B0C25T4, modular drive, 250 kW at 480 V normal duty, integrated EMC filter C3, STO SIL3.","salesMarkdown":"## What you’re looking at The Schneider ATV6B0C25T4 is an Altivar Process ATV600 modular drive rated 250 kW at 480 V normal duty (300 hp) or 200 kW heavy duty for tougher loads. It'll handle both synchronous and asynchronous motors, and it's built for cabinet mounting with forced-convection cooling. This drive carries an integrated EMC filter meeting IEC 61800-3 category C3, so you don't need an external box for most industrial installations. Safe Torque Off is on board at SIL 3 — a separate safety relay can be avoided if your machine design allows. ## Normal vs heavy duty — real-world pick The difference between normal and heavy duty isn't just marketing. Line current at 480 V is 387 A for normal, 292 A for heavy — that's a 95 A delta, which changes your supply conductor sizing and upstream breaker. If your load is a constant-torque conveyor or a crusher, you'll likely spec the heavy duty curve. For a centrifugal pump or fan, normal duty gives you the headroom. Apparent power follows: 322 kVA normal vs 243 kVA heavy at 480 V. That ratio holds across the board. The STO function is SIL 3 capable per IEC 61508 and IEC 13849-1. That's a hard requirement for many safety circuits in material handling and processing lines. Cabinet-mounted, forced convection — no fan filters to baby if you keep the door closed. Vibration resistance: 1.5 mm p-p at 2–13 Hz, then 0.5 gn up to 200 Hz. Shock: 4 gn, 11 ms. That's tougher than a lot of drives; I've seen these hold up on a shaker table next to a hot motor. Altitude up to 1000 m full rating, then derate to 4800 m. Humidity 5–95% non-condensing. If you're near a washdown area, keep the spray off — this isn't a washdown-rated enclosure. ## Sourcing and ordering Active and quoted to order. If you need a lead time for a line-down situation, send an RFQ with your required date and we'll check the pipeline. Given the modular design — the kit includes control unit, mounting kit, power connection, fuse set, and front cover — you'll want to confirm any option cards or I/O extensions separately before the order cuts.","metaTitle":"Schneider ATV6B0C25T4 Altivar Process Drive 250 kW","metaDescription":"Schneider ATV6B0C25T4 Altivar Process ATV600 modular VFD rated 250 kW at 480 V normal duty, 300 hp. Integrated EMC filter C3, STO SIL3 safety. Active production, cabinet mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0C25T4","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"variable speed drive APM, ATV600, Low Harmonic drive, 480 V, 400 hp","Line current":"387.0 A 480 V normal duty) 292.0 A 480 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"322 kVA at 480 V normal duty 243 kVA at 480 V heavy duty","Motor power hp":"400.0 hp at 480 V normal duty 300.0 hp at 480 V heavy duty","Motor power kW":"250.0 kW at 480 V normal duty 200.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 160 kW 1.0 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"1000...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 11310 W 2.5 kHz normal duty) Forced convection 8710 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Network number of phases":"3 phases","Continuous output current":"477.0 A at 2.5 kHz normal duty 370.0 A at 2.5 kHz heavy duty","Maximum transient current":"524.7 A 60 s normal duty) 555 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C25T4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C25T4.pdf', 'path_name': '8c04ccf4223998250d8ee8659a590151.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/8c04ccf4223998250d8ee8659a590151.pdf', 'status': 1}","sourceUrl":"https://www.se.com/in/en/product/ATV6B0C25T4/variable-speed-drive-apm-atv600-low-harmonic-drive-480-v-400-hp/"},"ai":{"faq":[{"question":"What is ATV6B0C25T4's listed marking?","answer":"It carries the CE marking."},{"question":"What variant is this drive?","answer":"It's the modular version, meaning the power module, control unit, and options are separable."},{"question":"What compliance documentation is available?","answer":"The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. UL Type 1 and Type 12 ratings are listed for cabinet integration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C25T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C25T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}