{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C25T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C25T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C25T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C25T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular version CE marked, 250 hp at 600 V normal duty, 200 hp heavy duty, forced convection cooling, cabinet mount.","salesMarkdown":"## Drive selection memo: normal vs heavy duty and safety bundling The ATV6B0C25T6 is a modular Altivar Process ATV600 drive rated 250 hp normal duty and 200 hp heavy duty at 600 V, drawing 199 A / 160 A line current respectively. Apparent power sits at 207 kVA normal duty, 166 kVA heavy duty. Integrated safe torque off (STO) to SIL 3 means this drive can serve a safety function without an external contactor for the power removal – one less component in the panel. The safety function is delivered on the control board, so wiring to the drive's STO terminals is straightforward for the integrator. The built-in EMC filter meets IEC 61800-3 category C3 for cable runs up to 300 m (984.3 ft). That covers most industrial runs inside a plant; if your line side is close to a residential mains, you may need an external filter for C2 compliance. The filter is pre-installed, so no separate ordering step for a typical machine builder. ## Compliance and standards stack The drive carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental classification), IEC 61508 / IEC 13849-1 (functional safety), and UL 61800-5-1. Pollution degree 2 per IEC 61800-5-1 suits typical controlled environments. Total harmonic current distortion (THDI) is below 5 % at full load per IEEE 519, so you can usually skip an external line reactor unless the supply is very weak. Prospective line short-circuit current rating is 50 kA – check your available fault current against that when selecting upstream overcurrent devices. ## Communication and I/O expansion The drive comes with a Modbus serial port (RTU, 2-wire RS-485, 1–247 addresses) and a Modbus TCP/Ethernet port (10/100 Mbit/s, half/full duplex, auto-negotiation). Slot A accepts a communication module for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). Slot A also accepts a digital/analog I/O extension or output relay extension module, and Slot B can take a second extension module. For a PROFINET or EtherNet/IP installation, order the appropriate option card separately; the base unit does not include one. Switching frequency is adjustable 2 to 4.9 kHz with derating; higher frequencies reduce motor noise but may require a larger drive frame if current is near the rating. ## Mounting and environmental Cabinet-mount only (UL type 1 or type 12 conduit box integration). Forced convection cooling – keep clearances per the instruction sheet for airflow. Shock tested to 4 gn for 11 ms per IEC 60068-2-27, vibration 1.5 mm peak-to-peak at 2–13 Hz and 0.5 gn at 13–200 Hz per IEC 60068-2-6.","metaTitle":"Schneider ATV6B0C25T6 Altivar Process 600, 250 HP at 600 V","metaDescription":"ATV6B0C25T6 is an active-production modular AC drive rated 250 hp normal duty at 600 V, with integrated EMC filter C3 and STO SIL 3. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C25T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 600 V, 250 hp","Line current":"199.0 A 600 V normal duty) 160.0 A 600 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"207 kVA at 600 V normal duty 166 kVA at 600 V heavy duty","Motor power hp":"250.0 hp at 600 V normal duty 200.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 8180 W 2.5 kHz normal duty) Forced convection 6510 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"275.0 A at 2.5 kHz normal duty 215.0 A at 2.5 kHz heavy duty","Maximum transient current":"302.5 A 60 s normal duty) 322.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C25T6?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C25T6.pdf', 'path_name': '71a59dd6392445b3bfbde102cdc567c2.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/71a59dd6392445b3bfbde102cdc567c2.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C25T6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-600-v-250-hp/"},"ai":{"faq":[{"question":"What marking does the ATV6B0C25T6 carry?","answer":"It carries the CE marking."},{"question":"What is the variant of this drive?","answer":"The variant is listed as a modular version."},{"question":"What compliance documentation is available for the ATV6B0C25T6?","answer":"The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. Detailed declarations are available from the manufacturer, typically upon request or via their documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C25T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C25T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}