{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C31Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C31Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C31Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C31Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, modular version ATV6B0C31Q6, 315 kW normal duty at 690 V, 287 A line current, integrated C3 EMC filter, STO SIL3 safety.","salesMarkdown":"## Fieldbus and safety integration The ATV6B0C31Q6: This modular ATV6B0 variant covers synchronous and asynchronous motors up to 315 kW on a 690 V normal-duty profile, or 250 kW in heavy duty. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen via RJ45 / SUB-D 9 / screw terminals; for I/O expansion a second slot (A/B) handles relay and analog/digital extension modules. The native Modbus serial interface runs at up to 38.4 kbit/s, RTU or ASCII, with configurable parity and 1–247 node addressing. For SIL 3 applications the Safe Torque Off circuit is built into the drive — no external safety contactor required, reducing panel clutter and wiring. ## Cabinet integration and mounting Cabinet mount only — no through-panel or back-box version. Forced convection cooling (fans) requires clearances per the installation manual; the 73 dB noise level at rated load means acoustic consideration in occupied spaces. The kit includes the control unit, mechanical mounting kits, power connection set with fuses, a 200 kW power module, and front cover. Line-side connection uses M10 x 2 bars; motor side similarly M10 x 2 bars. Control wiring via removable screw terminals accepting 0.5–1.5 mm² (AWG 20–16). Prospective line Isc is 50 kA, so verify upstream SCCR. For altitudes above 1000 m derate current; up to 2000 m is acceptable with derating. Vibration resistance 1.5 mm p-p (2–13 Hz) and 0.5 gn (13–200 Hz) per IEC 60068-2-6; shock resistance 4 gn for 11 ms. The modular form factor simplifies replacement of the power section separately from the control unit.","metaTitle":"ATV6B0C31Q6 Altivar Process ATV600 Drive, 315 kW Normal Duty","metaDescription":"ATV6B0C31Q6 modular drive in current production. 315 kW/690V normal duty, STO SIL3, integrated EMC filter C3. Sourced to order – RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C31Q6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 690 V, 315 kW","Line current":"287.0 A 690 V normal duty) 228.0 A 690 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"343 kVA at 690 V normal duty 273 kVA at 690 V heavy duty","Motor power kW":"315.0 kW at 690 V normal duty 250.0 kW at 690 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 11760 W 2.5 kHz normal duty) Forced convection 9440 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"340.0 A at 2.5 kHz normal duty 275.0 A at 2.5 kHz heavy duty","Maximum transient current":"374 A 60 s normal duty) 412.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C31Q6?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C31Q6.pdf', 'path_name': 'a955c931adf0c3bd271e77131d728366.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/a955c931adf0c3bd271e77131d728366.pdf', 'status': 1}","sourceUrl":"https://www.se.com/in/en/product/ATV6B0C31Q6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-690-v-315-kw/"},"ai":{"faq":[{"question":"What compliance documentation does the ATV6B0C31Q6 carry?","answer":"The drive is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. It includes integrated EMC filter for category C3 environments and meets IEEE 519 harmonic limits (<5% THDI at full load)."},{"question":"What is the listed variant of the ATV6B0C31Q6?","answer":"It is the Modular version, delivered as a kit with control unit, power module, mounting kits, fuses, and front cover."},{"question":"What marking does the ATV6B0C31Q6 display?","answer":"It carries the CE marking."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C31Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C31Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}