{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C31T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C31T6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C31T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C31T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular VFD, ATV6B0C31T6, 350 hp / 277 A at 600 V normal duty, 250 hp / 199 A heavy duty, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"## Drive fit and sourcing reality The ATV6B0C31T6: The integrated EMC filter covers 984.3 ft (300 m) of motor cable to IEC 61800-3 category C3 — enough for most industrial runs without an external box. STO SIL 3 is onboard; no separate safety relay needed for torque-off functions. Lifecycle is current production — no EOL bulletin, no LTB pending. This is a factory-order line, quoted against an RFQ. If you're freezing a BOM this quarter, it's a clean placement. Normal duty (350 hp) handles continuous loads like pumps or fans; heavy duty (250 hp) covers constant-torque conveyors or extruders. The line current number is the one for cable and fuse sizing — 277 A normal, 199 A heavy. SCCR on the line side is 50 kA prospective; coordinate with upstream breaker accordingly. Switching frequency is adjustable 2–4.9 kHz with derating. No forced convection rating surprise — it is all forced convection (fan-cooled). Mount inside a cabinet that can move 73 dB of noise — that's the fan at full tilt. ## Fieldbus and safety integration Slot A on the control module accepts a fleet of communication option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). Slot A/B also handle digital/analog I/O or relay extension. Ethernet is 10/100 Mbit, Modbus serial RTU over 2-wire RS-485 at 4.8–38.4 kbit/s. Safe torque off (STO) is SIL 3 certified. If you need a drive-based safety category, this saves wiring a contactor. The drive carries CE marking and complies with IEC 61800-3, -5-1, -61000-3-12, -60721-3, IEC 61508, and UL 61800-5-1. Pollution degree 2, IP rating is UL Type 1 or 12 when cabinet-mounted. Operating altitude to 2000 m (derate above 1000 m).","metaTitle":"Schneider ATV6B0C31T6 Altivar Process ATV600, 350 HP 600 V","metaDescription":"Schneider Electric ATV6B0C31T6 Altivar Process ATV600 drive. 350 hp normal duty, 250 hp heavy duty at 600 V. Integrated EMC filter C3, STO SIL 3. Current production, sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0C31T6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 600 V, 350 hp","Line current":"277.0 A 600 V normal duty) 199.0 A 600 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"288 kVA at 600 V normal duty 207 kVA at 600 V heavy duty","Motor power hp":"350.0 hp at 600 V normal duty 250.0 hp at 600 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 11430 W 2.5 kHz normal duty) Forced convection 8180 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"340.0 A at 2.5 kHz normal duty 275.0 A at 2.5 kHz heavy duty","Maximum transient current":"374 A 60 s normal duty) 412.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C31T6?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C31T6.pdf', 'path_name': 'efbf8d671e1a5d6f967ad6a21d0a5e0b.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/efbf8d671e1a5d6f967ad6a21d0a5e0b.pdf', 'status': 1}","sourceUrl":"https://www.se.com/in/en/product/ATV6B0C31T6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-600-v-350-hp/"},"ai":{"faq":[{"question":"What are the key standby / motor power ratings?","answer":"350 hp at 600 V normal duty (277 A line current) and 250 hp at 600 V heavy duty (199 A line current). Apparent power is 288 kVA normal, 207 kVA heavy."},{"question":"What communication protocols does this drive support?","answer":"Via slot A option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen. Onboard: Modbus serial RTU (2-wire RS-485) and Ethernet/Modbus TCP."},{"question":"What are the environmental limits for installation?","answer":"Operating temperature range not explicitly listed, but humidity 5–95% non-condensing, shock 4 gn/11 ms, vibration 1.5 mm at 2–13 Hz and 0.5 gn at 13–200 Hz. Altitude up to 2000 m with derating above 1000 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C31T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C31T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}