{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C45T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C45T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C45T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C45T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 drive, ATV6B0C45T4, modular version, 450 kW normal duty at 480 V, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The ATV6B0C45T4 is a modular Altivar Process ATV600 drive rated for 450 kW normal duty (650 hp) and 355 kW heavy duty at 480 V. It runs both asynchronous and synchronous motors. The integrated EMC filter is rated for Category C3 with up to 300 m (984.3 ft) of motor cable, covering most industrial installations without an external filter. Safe torque off (STO) is SIL 3-rated — any substitution or gray-market unit that breaks the chain of custody invalidates that safety rating. ## Lifecycle & compliance — planning letter Lifecycle status is active (current production). Do not assume that a lower-priced unit from a non-authorized broker carries the same factory calibration or warranty — the safety and EMC compliance (IEC 61800-3, IEC 61508) relies on full manufacturing traceability. The marking listed is CE, and the drive complies with IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, and IEC 13849-1. If you need a formal Declaration of Conformity or a specific UL file, request it through the authorized channel; it is not included in the bill-of-materials documentation from alternative sources. ## Authorized-channel sourcing note The modular version ships the power module (160 kW) and control unit separately. The front cover and connection kit are supplied separately for field assembly. ## Mounting & environment checklist Cabinet mount with forced-convection cooling. Switching frequency adjustable 2.5–8 kHz with derating; operating altitude to 1000 m without derating then up to 4800 m with derating; pollution degree 2; vibration 0.5 gn at 13–200 Hz; shock 4 gn for 11 ms. ## Fieldbus & integration Modbus serial and Modbus TCP/Ethernet/IP on board. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or I/O extension modules. Transmission rate up to 100 Mbit/s on Ethernet, 38.4 kbit/s on serial. For a new line, commission with the factory-stocked communication module from the same authorized lot to avoid firmware mismatches that can cause bus timeouts. ## Current & fault handling Line current: 626 A at 480 V normal duty, 533 A heavy duty. Prospective line Isc rating 50 kA — adequate for most industrial services. Total harmonic current distortion (THDI) is <5% at full load per IEEE 519. The drive includes protection for motor phase break, ground fault, overvoltage, undervoltage, overspeed, and DC bus overvoltage. For a field swap, confirm the existing line reactor and braking resistor match the DC injection braking method; there is no AC regenerative braking option listed.","metaTitle":"Schneider ATV6B0C45T4 Altivar Process ATV600, 450 kW","metaDescription":"Active production; integrated EMC filter C3; STO SIL 3 safety; 450 kW normal duty at 480 V. Modular version from authorized channel only for full traceability. ATV6B0C45T4 datashee","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0C45T4","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"75 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"variable speed drive APM, ATV600, Low Harmonic drive, 480 V, 650 hp","Line current":"626.0 A 480 V normal duty) 533.0 A 480 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"520 kVA at 480 V normal duty 443 kVA at 480 V heavy duty","Motor power hp":"650.0 hp at 480 V normal duty 550.0 hp at 480 V heavy duty","Motor power kW":"450.0 kW at 480 V normal duty 355.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 3.0 power module 160 kW 2.0 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"1000...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 19530 W 2.5 kHz normal duty) Forced convection 15740 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Network number of phases":"3 phases","Continuous output current":"830.0 A at 2.5 kHz normal duty 660.0 A at 2.5 kHz heavy duty","Maximum transient current":"913 A 60 s normal duty) 990 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C45T4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C45T4.pdf', 'path_name': '62b4c7fc6a57b670737734b510594f2e.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/62b4c7fc6a57b670737734b510594f2e.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C45T4/variable-speed-drive-apm-atv600-low-harmonic-drive-480-v-650-hp/"},"ai":{"faq":[{"question":"What marking is listed for the ATV6B0C45T4?","answer":"The drive carries the CE marking. Compliance documentation includes IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1."},{"question":"What variant is the ATV6B0C45T4?","answer":"It is a modular version. The power module (160 kW), control unit, front cover, and connection kit are supplied separately for field assembly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C45T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C45T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}