{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C56T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C56T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C56T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C56T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, ATV6B0C56T4, modular VFD, 800 hp at 480 V normal duty, 560 kW, 771 A line current, cabinet mount.","salesMarkdown":"## Modular high-power drive for process applications ATV6B0C56T4 is the modular version of the Altivar Process ATV600 family—a cabinet-mount drive module rated 800 hp (560 kW) at 480 V normal duty, 650 hp (450 kW) heavy duty. Line current pulls 771 A at normal duty, 626 A under heavy duty. Designed for synchronous and asynchronous motors, with DC injection braking and an adjustable switching frequency of 2.5 to 8 kHz (derated above 2 kHz). Modular version means the kit includes the control unit, power module, mechanical mounting kit, power connections, and a set of fuses—you supply the enclosure and integrate per the cabinet mount instructions. Communication is handled via the built-in Modbus serial (RTU, 2-wire RS485, 1–247 addresses) and a dual Ethernet port supporting Modbus TCP/IP at 10/100 Mbit/s. Slot A accepts optional Profibus DP V1, PROFINET, DeviceNet, CANopen, or I/O extension cards. ## Compliance and safety planning Integrated EMC filter meets IEC 61800-3 category C3 for 984.3 ft (300 m) cable. Prospective line short-circuit current rated 50 kA. Pollution degree 2 per IEC 61800-5-1, 5–95% non-condensing humidity, and operation up to 4800 m with derating above 1000 m.","metaTitle":"ATV6B0C56T4 Altivar Process ATV600, 800 hp, 480 V","metaDescription":"Active production ATV6B0C56T4 modular drive, 800 hp at 480 V normal duty, 771 A line current. IEC/UL compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0C56T4","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"77 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"variable speed drive APM, ATV600, Low Harmonic drive, 480 V, 800 hp","Line current":"771.0 A 480 V normal duty) 626.0 A 480 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"641 kVA at 480 V normal duty 520 kVA at 480 V heavy duty","Motor power hp":"800.0 hp at 480 V normal duty 650.0 hp at 480 V heavy duty","Motor power kW":"560.0 kW at 480 V normal duty 450.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 4.0 power module 160 kW 3.0 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"1000...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 24060 W 2.5 kHz normal duty) Forced convection 19160 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Network number of phases":"3 phases","Continuous output current":"1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty","Maximum transient current":"1122 A 60 s normal duty) 1245 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C56T4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C56T4.pdf', 'path_name': '0f32671f938612e09aac74328da084c4.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/0f32671f938612e09aac74328da084c4.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C56T4/variable-speed-drive-apm-atv600-low-harmonic-drive-480-v-800-hp/"},"ai":{"faq":[{"question":"What is ATV6B0C56T4's listed marking (CE) on this component line?","answer":"CE marking is listed."},{"question":"What is ATV6B0C56T4's listed variant?","answer":"Modular version for cabinet integration."},{"question":"What compliance documentation does this brand provide for ATV6B0C56T4 (RoHS, REACH, UL, IEC)?","answer":"The drive meets IEC 61800-3, IEC 61800-5-1, IEC 61508 SIL 3 for safety, and UL 61800-5-1 (UL type 1/12 when cabinet integrated)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C56T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C56T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}