{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0C71T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0C71T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0C71T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0C71T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular version, ATV6B0C71T4, 1000 hp (710 kW) normal duty at 480 V, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The ATV6B0C71T4 is a modular Altivar Process ATV600 drive from Schneider Electric, rated for 1000 hp (710 kW) normal duty and 800 hp (560 kW) heavy duty at 480 V. It lands in the ATV6B0 chassis, cabinet-mounted, with forced convection cooling. Line current draws 958 A in normal duty and 771 A in heavy duty at 480 V. An integrated EMC filter meets IEC 61800-3 category C3 for cable runs up to 300 m. Current total harmonic distortion stays under 5% at full load per IEEE 519. The drive handles both synchronous and asynchronous motors, with adjustable switching frequency from 2.5 to 8 kHz (derated above 2.5 kHz). Braking to standstill via DC injection. Protection covers motor phase break, output short-circuit, DC bus overvoltage, line undervoltage, and more. Pollution degree 2 per IEC 61800-5-1 means the drive is suitable for control rooms and clean industrial environments; not for dusty or wet locations without additional enclosure. Vibration resistance is 1.5 mm peak-to-peak at 2–13 Hz, 0.5 gn at 13–200 Hz – standard for cabinet-mounted gear. Prospective line short-circuit current (Isc) rated at 50 kA – install on a supply with available fault current up to that value without upstream fusing for SCCR. Communication slots A accept fieldbus modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen. The onboard Modbus serial runs RTU at 4.8–38.4 kbit/s. Ethernet port (10/100 Mbit/s) supports half/full duplex and auto-negotiation.","metaTitle":"Schneider ATV6B0C71T4 Altivar Process Drive, 1000 HP, 480 V,","metaDescription":"ATV6B0C71T4 is an active Altivar Process ATV600 modular drive, 1000 hp/710 kW normal duty at 480 V, with integrated EMC filter C3, STO SIL3, and multiple fieldbus options. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0C71T4","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"78 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"variable speed drive APM, ATV600, Low Harmonic drive, 480 V, 1000 hp","Line current":"958.0 A 480 V normal duty) 771.0 A 480 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"797 kVA at 480 V normal duty 641 kVA at 480 V heavy duty","Motor power hp":"1000.0 hp at 480 V normal duty 800.0 hp at 480 V heavy duty","Motor power kW":"710.0 kW at 480 V normal duty 560.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 5.0 power module 160 kW 4.0 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"1000...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 29930 W 2.5 kHz normal duty) Forced convection 23740 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Network number of phases":"3 phases","Continuous output current":"1260.0 A at 2.5 kHz normal duty 1020.0 A at 2.5 kHz heavy duty","Maximum transient current":"1386 A 60 s normal duty) 1530 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV6B0C71T4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV6B0C71T4.pdf', 'path_name': 'f69e8c125acd9a98e371092379fafaa3.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/f69e8c125acd9a98e371092379fafaa3.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV6B0C71T4/variable-speed-drive-apm-atv600-low-harmonic-drive-480-v-1000-hp/"},"ai":{"faq":[{"question":"What are the key motor power ratings?","answer":"Normal duty: 1000 hp (710 kW) at 480 V. Heavy duty: 800 hp (560 kW) at 480 V. Line currents are 958 A and 771 A respectively."},{"question":"What fieldbus options are available?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen (RJ45, SUB-D 9, or screw terminals). Onboard serial is Modbus RTU at up to 38.4 kbit/s."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0C71T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0C71T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}