{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0M10Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0M10Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0M10Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0M10Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV6B0M10Q6 modular drive, 1000 kW at 690 V normal duty, 800 kW heavy duty, integrated EMC filter, STO SIL3.","salesMarkdown":"## What this drive really is The Schneider Electric ATV6B0M10Q6 is a modular Altivar Process ATV600 drive rated for 1000 kW at 690 V in normal duty and 800 kW in heavy duty, with an integrated EMC filter meeting IEC 61800-3 category C3. It's a current-production unit, not a retired surplus find—though if you buy it through our channel, you get the same factory-sealed box without the authorized-distributor markup. ## The ratings that decide your BOM line Motor power: 1000 kW normal duty, 800 kW heavy duty at 690 V. Line current matches: 898 A normal, 718 A heavy at 690 V. That gives you a real number to size the input fusing and cable without derating guesswork. THDI under 5% at full load per IEEE 519—no harmonic trap needed for most industrial feeds. Apparent power: 1073 kVA normal, 859 kVA heavy. That's the number the transformer guy wants. ## Safety and compliance without add-ons STO Safe Torque Off to SIL 3 is built in. That saves you an external safety relay and the wiring to it. The drive also bundles motor thermal protection, phase-break detection, and a full roster of supply-side safeguards—overvoltage, undervoltage, phase loss, and overcurrent between phases and earth. For CE marking you're covered against IEC 61800-3, -5-1, 61000-3-12, 60721-3, 61508, and 13849-1. The integrated C3 EMC filter handles 300 m of motor cable without an external box. ## Fieldbus flexibility in a modular frame The drive comes with Modbus serial and Modbus TCP as standard. Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (RJ45, SUB-D 9, or screw terminals), plus digital/analog I/O or relay extension modules that can also go in slot B. Switching frequency adjustable from 2 to 4.9 kHz with derating—drop it to 2 kHz if you're chasing the last amp out of the heat sink.","metaTitle":"Schneider ATV6B0M10Q6 Altivar Process Drive, 1000 kW 690V","metaDescription":"CE-marked Modbus/Profibus drive rated 1000 kW at 690V normal duty. Integrated EMC filter C3, STO SIL3. Modular with slot A/B options. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV6B0M10Q6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"78 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, Low Harmonic 690 V, 1000 kW","Line current":"898.0 A 690 V normal duty) 718.0 A 690 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"1073 kVA at 690 V normal duty 859 kVA at 690 V heavy duty","Motor power kW":"1000.0 kW at 690 V normal duty 800.0 kW at 690 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 5.0 power module 200 kW 4 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 37000 W 2.5 kHz normal duty) Forced convection 29700 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"1030.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty","Maximum transient current":"1133 A 60 s normal duty) 1245 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6B0M10Q6/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-690-v-1000-kw/"},"ai":{"faq":[{"question":"What is the ATV6B0M10Q6's CE marking and variant?","answer":"It is CE marked and comes as a modular version, meaning the base drive is separate from communication or I/O option cards."},{"question":"What compliance documentation covers this drive?","answer":"It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets category C3 per IEC 61800-3, and the safety function is STO SIL3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0M10Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0M10Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}