{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6B0M10T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6B0M10T4","canonicalUrl":"https://aoctrl.com/schneider/ATV6B0M10T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6B0M10T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV6B0M10T4 modular AC drive, 1400 hp normal duty / 1100 hp heavy duty at 480 V, 1121 kVA normal duty, cabinet mount, STO SIL 3, integrated EMC filter C3.","salesMarkdown":"The ATV6B0M10T4 is rated 1400 hp at 480 V for normal-duty applications and 1100 hp at 480 V for heavy-duty applications, with corresponding apparent power of 1121 kVA and 961 kVA respectively. The heavy-duty rating governs continuous operation on constant-torque loads like conveyors or extruders; the normal-duty figure applies to variable-torque loads such as centrifugal pumps and fans where the drive can exploit the quadratic torque curve. Line current at 480 V is 1348 A for normal duty and 1156 A for heavy duty — these numbers drive the upstream breaker and cable sizing, not the motor FLA alone. ## Safety and protection — STO SIL 3 and integrated safeguards Protection covers motor thermal, drive thermal, overcurrent between output phases and earth, short-circuit, overvoltage on the DC bus, line supply phase loss, overspeed, and control circuit break — 16 distinct fault categories that map to specific Altivar parameter codes for diagnostics. ## Fieldbus and I/O — slot architecture and communication options Slot A accepts plug-in communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). Slot A and slot B also accept digital/analog I/O extension or output relay extension cards — this modularity lets the drive match the network topology without a separate gateway. Embedded Ethernet supports Modbus TCP with half/full duplex and auto-negotiation at 10/100 Mbit/s; a separate 2-wire RS-485 Modbus serial port runs at 4.8 to 38.4 kbit/s with RTU framing. The analog inputs (AI1–AI3) are software-configurable for voltage (0–10 V DC, 30 kOhm) or current (0–20 mA / 4–20 mA, 250 Ohm) with 12-bit resolution. Discrete inputs DI1–DI6 are programmable 24 V DC, with DI5 and DI6 configurable as pulse inputs up to 30 kHz — useful for encoder-less speed feedback or flowmeter counting. Sampling for digital inputs is 2 ms ±0.5 ms on DI1–DI4, 5 ms ±1 ms on DI5–DI6; analog inputs sample at 5 ms ±0.1 ms. ## Cabinet integration — mounting, cooling, and altitude derating Cabinet-mount design with forced-convection cooling — the drive relies on its own fan for airflow, so panel ventilation must be sized for the 79 dB noise level (86/188/EEC) and the heat dissipated at full load. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m shielded cable, which covers most industrial installations but may require an external filter for residential or public low-voltage networks. Operating altitude is 0–4800 m with current derating above 1000 m — for installations above 1000 m, the heavy-duty current rating must be reduced per the derating curve in the product manual. Pollution degree 2 per IEC 61800-5-1 means the drive is suitable for normal industrial environments with non-conductive contamination.","metaTitle":"Schneider ATV6B0M10T4 Altivar Process VFD, 1400 HP, 480 V","metaDescription":"Schneider Electric ATV6B0M10T4 Altivar Process ATV600 AC drive, 1400 HP normal duty at 480 V, 1100 HP heavy duty.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV6B0M10T4","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection","Marking":"CE","Variant":"Modular version","Accuracy":"+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"79 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"variable speed drive, Altivar Process ATV600, APM, Low Harmonic 480V, 1400hp","Line current":"1348.0 A 480 V normal duty) 1156.0 A 480 V heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Refresh time":"Relay output R1, R2, R3)5 ms +/- 0.5 ms)","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"1121 kVA at 480 V normal duty 961 kVA at 480 V heavy duty","Motor power hp":"1400.0 hp at 480 V normal duty 1100.0 hp at 480 V heavy duty","Motor power kW":"1000.0 kW at 480 V normal duty 800.0 kW at 480 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 6 power module 160 kW 5 front cover","Linearity error":"AI1, AI2, AI3 +/- 0.15 % of maximum value analog input AO1, AO2 +/- 0.2 % analog output","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Local signalling":"3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC 100000 cycles Configurable relay logic R2 sequence relay NO 100000 cycles Configurable relay logic R3 sequence relay NO 100000 cycles","Sampling duration":"2 ms +/- 0.5 ms DI1...DI4) - discrete input 5 ms +/- 1 ms DI5, DI6) - discrete input 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input 10 ms +/- 1 ms AO1) - analog output","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Analogue input type":"AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits","Discrete input type":"DI1...DI6 programmable, 24 V DC DI5, DI6 programmable as pulse input 0...30 kHz, 24 V DC STOA, STOB safe torque off, 24 V DC 2.2 kOhm","Input compatibility":"DI1...DI6 discrete input level 1 PLC IEC 61131-2 DI5, DI6 discrete input level 1 PLC IEC 65A-68 STOA, STOB discrete input level 1 PLC IEC 61131-2","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Analogue output type":"Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits Software-configurable current AO1, AO2 0...20 mA 10 bits","Discrete input logic":"Positive logic (source) DI1...DI6), < 5 V, > 11 V Negative logic (sink) DI1...DI6), > 16 V, < 10 V Positive logic (source) DI5, DI6), < 0.6 V, > 2.5 V Positive logic (source) STOA, STOB), < 5 V, > 11 V","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 45420 W 2.5 kHz normal duty) Forced convection 36940 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"1770.0 A at 2.5 kHz normal duty 1420.0 A at 2.5 kHz heavy duty","Maximum switching current":"Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC","Maximum transient current":"1947 A 60 s normal duty) 2130 A 60 s heavy duty)","Minimum switching current":"Relay output R1, R2, R3 5 mA 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V - 10...10 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV6B0M10T4/variable-speed-drive-altivar-process-atv600-apm-low-harmonic-480v-1400hp/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV6B0M10T4?","answer":"The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. RoHS and REACH declarations are part of the standard documentation package from Schneider."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6B0M10T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6B0M10T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}