{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV930C16N4F","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV930C16N4F","canonicalUrl":"https://aoctrl.com/schneider/ATV930C16N4F","factsUrl":"https://aoctrl.com/api/mcp/products/ATV930C16N4F","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV900 series, ATV930C16N4F, variable speed drive, 160 kW normal duty (132 kW heavy), 302 A, 380...440 V, IP21, floor-standing, without braking chopper.","salesMarkdown":"ATV930C16N4F is the standard version without braking chopper from the Altivar Process ATV900 range, sized for 160 kW normal duty / 132 kW heavy duty on a 380–440 V three-phase supply. Nominal output current is 302 A at 2.5 kHz switching frequency for normal duty, dropping to 250 A for heavy-duty applications. The IP21 enclosure is designed for floor-standing installation — no wall-mount brackets here, so plan panel floor space accordingly. Line and motor connections use M12 bars — torque to manufacturer specifications, not by feel. Control wiring lands on removable screw terminals, 0.5–1.5 mm². Integrated EMC filter covers conducted emissions; the optional EMC plate (sold separately) finishes the shield termination scheme. The drive includes internal 24 V DC supplies for digital inputs (21–27 V for STO and digital inputs, 19–30 V for the reference potentiometer). This is a catalog-standard Altivar Process drive; sourcing lead times run quoted to order. If you are holding a BOM freeze, this part number is stable. No direct replacement or cross-reference exists within the same ATV930 frame — variants with a braking chopper carry a different order code, so verify your braking resistor requirement before specifying.","metaTitle":"Schneider ATV930C16N4F Altivar Process Drive, 160 kW, IP21","metaDescription":"ATV930C16N4F is in active production. 160 kW normal duty / 132 kW heavy duty, 302 A, 380–440 V, IP21 floor-standing, integrated EMC filter. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV930C16N4F","Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"Standard version Without braking chopper","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"69 dB","description":"variable speed drive, Altivar Process ATV900, floor standing ATV930, 160kW, 400 to 440V, without braking unit, IP21","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Floor-standing","Option Module":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for EtherCAT Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A/slot B/slot C: digital and analog I/O extension module Slot A/slot B/slot C: output relay extension module Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module communication module for Ethernet Powerlink","Assembly style":"In floor-standing enclosure","Motor power kW":"160.0 kW for normal duty 132.0 kW for heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of product":"Altivar Process ATV900","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Transmission rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device application":"Industrial application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm² Line side: M12 bar Motor: M12 bar","Volume of cooling air":"720 m3/h","Nominal Output Current":"302.0 A","IP degree of protection":"IP21","Network number of phases":"3 phases","Continuous output current":"302 A at 2.5 kHz for normal duty 250 A at 2.5 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...440 V","Communication port protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Product specific application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-15...40 °C (without derating) 40...50 °C (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/ATV930C16N4F/variable-speed-drive-altivar-process-atv900-floor-standing-atv930-160kw-400-to-440v-without-braking-unit-ip21/"},"ai":{"faq":[{"question":"What supply voltage does this drive require?","answer":"Rated supply voltage is 380...440 V, three-phase."},{"question":"Does the ATV930C16N4F include an EMC filter?","answer":"An EMC filter is integrated, with an optional EMC plate to complete the installation for full compliance."},{"question":"What is the protection rating of this drive?","answer":"IP21 for indoor, floor-standing use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV930C16N4F","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV930C16N4F when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}