{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV930D11M3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV930D11M3","canonicalUrl":"https://aoctrl.com/schneider/ATV930D11M3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV930D11M3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV900, ATV930D11M3, variable speed drive, 11 kW normal duty, 7.5 kW heavy duty, 200-240 V 3-phase, braking chopper, IP21.","salesMarkdown":"## Sourcing and compliance paperwork Compliance documentation covers UL 508C and multiple IEC standards including 61800-5-1 and 61800-3. The US category code US1CP4E22276 appears on the nameplate, which helps customs clearance for shipments into the US. The CE marking is on the drive itself, and the standards list covers most industrial applications across North America and Europe. ## Mounting and communication options Wall-mount form factor with IP21 / UL Type 1 protection suits indoor panel installations. Forced-air cooling requires 215 m3/h (56798.008 Gal/hr(US)) minimum airflow — ensure the enclosure has adequate ventilation or a fan. Operating position vertical +/- 10 degree. Communication is handled via Modbus TCP, EtherNet/IP, and serial Modbus on the base unit. Slot A accepts a communication module for PROFIBUS, PROFINET, EtherCAT, or CANopen, and there are additional slots for digital/analog I/O extension or encoder feedback modules. The backplane supplies 24 V DC internally for digital inputs and STO (21-27 V), with a separate 10.5 V DC for a potentiometer reference. Control wiring uses screw terminals handling 0.5 to 1.5 mm² (AWG 20-16). Power terminals on the line, DC bus, and motor side accept up to 16 mm² (AWG 6). Strip lengths follow standard practice; no special crimping tools needed beyond the usual for this gauge.","metaTitle":"Schneider ATV930D11M3 Altivar Process Drive, 11 kW ND, 3-pha","metaDescription":"Active-production ATV930D11M3 Altivar Process drive. 11 kW ND/7.5 kW HD, 200-240V 3-phase, braking chopper, EMC filter. UL and IEC certified. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Phase":"3 phase","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"Standard version With braking chopper","Category":"US1CP4E22276","Standards":"UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"59.5 dB","Maximum THDI":"<48 % from 80...100 % of load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting Mode":"Wall mount","Option Module":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink","Assembly style":"Enclosed","Motor power kW":"11.0 kW normal duty 7.5 kW heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV900","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission Rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device Application":"Industrial Application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Synchronous motors Asynchronous motors","Degree of protection":"UL type 1","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal 10...16 mm² AWG 8...AWG 6 DC bus screw terminal 10...16 mm² AWG 8...AWG 6 Motor screw terminal 16 mm² AWG 6","Nbr. of units in pkg.":"1","Volume of cooling air":"56798.008 Gal/hr(US) (215 m3/h)","Nominal Output Current":"46.8 A","IP degree of protection":"IP21","Continuous output current":"46.8 A 4 kHz normal duty 32.7 A 4 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V","Communication Port Protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product Specific Application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,291.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c48cf12f3c9521480f983584fe8cd32a.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV930D11M3/alternatives.json"},"ai":{"faq":[{"question":"What phase and voltage does ATV930D11M3 support?","answer":"It is a 3-phase drive rated for a supply voltage of 200 to 240 V."},{"question":"What internal power supplies does the drive provide?","answer":"It provides an external 24 V DC supply for digital inputs (19-30 V range), an internal 10.5 V DC supply for a reference potentiometer (1 to 10 kΩ), and an internal 24 V DC supply for digital inputs and STO (21-27 V)."},{"question":"What compliance certifications does ATV930D11M3 carry?","answer":"The drive is UL 508C and IEC 61800-3 / IEC 61800-5-1 certified, among other IEC standards. It also carries CE marking and the US category code US1CP4E22276."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV930D11M3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV930D11M3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}