{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV930D55N4ZU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV930D55N4ZU","canonicalUrl":"https://aoctrl.com/schneider/ATV930D55N4ZU","factsUrl":"https://aoctrl.com/api/mcp/products/ATV930D55N4ZU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, variable speed drive, ATV930D55N4ZU, 55 kW normal duty / 45 kW heavy duty, 106 A, 380-480 V 3-phase, IP21, UL type 12.","salesMarkdown":"The Schneider ATV930D55N4ZU is an Altivar Process ATV900 variable speed drive sized for 55 kW normal duty or 45 kW heavy duty on a 380-480 V 3-phase supply. It delivers 106 A continuous at 2.5 kHz in normal duty, 88 A in heavy duty. Built-in braking chopper, integrated EMC filter, and a full set of fieldbus options (EtherNet/IP, Modbus TCP, Modbus serial, plus slot-based Profibus DP, PROFINET, DeviceNet, EtherCAT, CANopen, and Ethernet Powerlink). The 55 kW normal duty / 45 kW heavy duty split is the key sizing decision. Normal duty covers variable-torque loads like fans and pumps; heavy duty handles constant-torque or high-starting-torque applications such as conveyors or extruders. The 106 A nominal output current is the headline number, but the continuous output current at switching frequency tells the real story: 106 A at 2.5 kHz for normal duty, 88 A at 2.5 kHz for heavy duty. If your application needs a higher carrier frequency for quieter motor operation, expect derating beyond those figures. The drive accepts 380-480 V 3-phase input and includes an integrated EMC filter (with an optional EMC plate for stricter emissions). The IP21 enclosure and UL type 12 rating mean it's protected against dust and dripping water — fine for a clean control room, but not for washdown areas. Cabinet-mount only, vertical +/-10°, with a heat sink. Requires 295 m³/h of cooling air. Control wiring uses screw terminals accepting 0.5-1.5 mm² (AWG 20-16). Communication defaults to EtherNet/IP and Modbus TCP on the built-in port, with Modbus serial as a fallback. For other fieldbuses, slot A accepts Profibus DP, PROFINET, DeviceNet, EtherCAT, or CANopen modules. Slots A, B, and C also accept digital/analog I/O or relay extension modules; slot B can host encoder interfaces (digital 5/12 V, analog, or resolver). The PID regulator is adjustable onboard, so closed-loop control for pressure, flow, or level doesn't require an external controller. Carries CE marking and complies with UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic), IEC 60721-3 (environmental), IEC 61508, and IEC 13849-1 (functional safety). The integrated STO (Safe Torque Off) supply is 24 V DC, 21-27 V — separate from the digital input supply (24 V DC, 19-30 V). The internal 10.5 V DC reference for a 1-10 kΩ potentiometer is available for local speed reference without an external power supply.","metaTitle":"Schneider ATV930D55N4ZU Altivar Process Drive, 55 kW, 106 A","metaDescription":"Schneider ATV930D55N4ZU Altivar Process ATV900 drive, 55 kW normal duty / 45 kW heavy duty, 106 A nominal output, 380-480 V 3-phase. Active production, sourced to order. RFQ for le","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Phase":"3 phase","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"With braking chopper Standard version","Category":"US1CP4E22278","Standards":"UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"68.3 dB","Maximum THDI":"<48 % from 80...100 % of load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting Mode":"Cabinet mount","Option Module":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink","Assembly style":"With heat sink","Motor power kW":"55.0 kW normal duty 45.0 kW heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV900","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission Rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device Application":"Industrial Application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 12","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal 70...120 mm² AWG 1/0...250 kcmil Motor screw terminal 70...120 mm² AWG 1/0...250 kcmil DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil","Nbr. of units in pkg.":"1","Volume of cooling air":"77932.2 Gal/hr(US) (295 m3/h)","Nominal Output Current":"106.0 A","IP degree of protection":"IP21","Continuous output current":"106 A 2.5 kHz normal duty 88 A 2.5 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication Port Protocol":"EtherNet/IP Modbus TCP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product Specific Application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/ATV930D55N4ZU/variable-speed-drive-altivar-process-atv900-atv930-75hp-380-to-480v-cabinet-integration-ip20-for-us/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV930D55N4ZU/alternatives.json"},"ai":{"faq":[{"question":"What is the listed phase for this drive?","answer":"3-phase input."},{"question":"What is the supply voltage range?","answer":"380-480 V AC, 3-phase. The control logic requires external 24 V DC (19-30 V) for digital inputs, and a separate 24 V DC (21-27 V) for STO."},{"question":"What compliance documentation does this drive carry?","answer":"CE marked, UL 508C listed, and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV930D55N4ZU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV930D55N4ZU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}