{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV930D75N4C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV930D75N4C","canonicalUrl":"https://aoctrl.com/schneider/ATV930D75N4C","factsUrl":"https://aoctrl.com/api/mcp/products/ATV930D75N4C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV930D75N4C variable speed drive, 75 kW normal duty / 55 kW heavy duty, 380-480 V 3-phase, 145 A nominal output current, IP21, wall-mount.","salesMarkdown":"## 75 kW normal duty, 55 kW heavy duty — the rating that decides the motor The ATV930D75N4C is a 380-480 V 3-phase variable speed drive from the Altivar Process ATV900 series, rated 75 kW normal duty and 55 kW heavy duty at 145 A continuous output current (2.5 kHz switching frequency). The heavy duty figure governs constant-torque loads — conveyors, extruders, positive-displacement pumps — where the motor pulls rated torque across the speed range. Normal duty applies to variable-torque loads like centrifugal pumps and fans where torque falls with speed. ## IP21 enclosure, wall-mount — clean indoor installation only IP21 / UL Type 1 protection means the drive is suitable for indoor, non-condensing environments where tools are required for access. No washdown rating — keep it out of wet or dusty areas. Wall-mount only, vertical within ±10°, with 295 m³/h of cooling air volume required. The control terminals accept 0.5-1.5 mm² (AWG 20-16); the DC bus and line/motor terminals take 95-120 mm² (AWG 3/0-250 kcmil). Operating altitude derating starts at 1000 m: 1 % current derating per 100 m above that. Pollution degree 2, overvoltage category III. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 1 gn at 13-200 Hz per IEC 60068-2-6; shock resistance is 15 gn for 11 ms per IEC 60068-2-27. ## Built-in Ethernet, fieldbus slots, and functional safety The drive ships with Modbus TCP, EtherNet/IP, and Modbus serial as standard communication ports. Three option slots (A, B, C) accept fieldbus modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, or Ethernet Powerlink, plus I/O extension and encoder interface modules. The integrated EMC filter meets IEC 61800-3 with an optional EMC plate for higher performance. Standards compliance includes UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61508, and IEC 13849-1 — the drive supports functional safety integration including STO (Safe Torque Off) via the 24 V DC internal supply. The adjustable PID regulator handles closed-loop process control without an external controller.","metaTitle":"Schneider Electric ATV930D75N4C AC Drive, 75 kW, 380-480 V","metaDescription":"Schneider Electric ATV930D75N4C Altivar Process ATV900 AC Drive, 75 kW normal duty / 55 kW heavy duty, 380-480 V 3-phase, 145 A output, IP21.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Phase":"3 phase","title":"ATV930D75N4C","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"Standard version Without braking chopper","Category":"US1CP4E22277","Standards":"UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"68.3 dB","description":"variable speed drive, Altivar Process ATV900, ATV930, 75kW, 400 to 480V, without braking unit, IP21","Maximum THDI":"<48 % from 80...100 % of load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting Mode":"Wall mount","Option Module":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink","Assembly style":"Enclosed","Motor power kW":"75.0 kW normal duty 55.0 kW heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV900","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission Rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device Application":"Industrial Application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 1","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil Line side screw terminal 95...120 mm² AWG 3/0...250 kcmil Motor screw terminal 95...120 mm² AWG 3/0...250 kcmil","Nbr. of units in pkg.":"1","Volume of cooling air":"77932.2 Gal/hr(US) (295 m3/h)","Nominal Output Current":"145.0 A","IP degree of protection":"IP21","Continuous output current":"145 A 2.5 kHz normal duty 106 A 2.5 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication Port Protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product Specific Application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$11,390.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/ATV930D75N4C/variable-speed-drive-altivar-process-atv900-atv930-75kw-400-to-480v-without-braking-unit-ip21/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV930D75N4C?","answer":"The drive carries CE marking and UL listing per UL 508C. Standards compliance includes IEC 61800-3 (EMC), IEC 61800-5-1 (electrical safety), IEC 61000-3-12 (harmonic current emissions), IEC 60721-3 (environmental conditions), IEC 61508, and IEC 13849-1 (functional safety). RoHS and REACH declarations are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV930D75N4C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV930D75N4C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}