{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV930U22M3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV930U22M3","canonicalUrl":"https://aoctrl.com/schneider/ATV930U22M3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV930U22M3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV930U22M3, 200-240V 3-phase, 2.2 kW normal duty / 1.5 kW heavy duty, 11.2 A continuous output, with braking chopper, IP21, UL Type 1 wall-mount drive.","salesMarkdown":"This is the ATV930U22M3, a 3-phase 200-240V variable speed drive from Schneider's Altivar Process ATV900 family. It's a workhorse for asynchronous and synchronous motors up to 2.2 kW normal duty or 1.5 kW heavy duty. Coming straight from the factory with a braking chopper built in and an integrated EMC filter, it saves panel space and avoids two common add-on costs. Rated 11.2 A continuous output at 4 kHz for normal duty, and 8 A at 4 kHz for heavy duty. That 11.2 A figure is what you'll refer to for cable sizing and thermal overload selection. The drive also carries a THDI below 48% at full load per IEC 61000-3-12, so it won't trash the plant power quality like some older PWM drives. It's covered by UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), and IEC 61508 / IEC 13849-1 for functional safety. Marked CE and UL Type 1. For a plant QC review or CE declaration file, those standards are the checklist. Wall-mount, IP21, UL Type 1. Cooling air volume is 38 m³/h (10038.7 Gal/hr (US)), so leave clearance around the heatsink. Main power terminals accept 2.5-6 mm² (AWG 14-10); control terminals 0.5-1.5 mm² (AWG 20-16). The drive generates its own 24VDC supply for digital inputs and STO, plus a 10.5VDC reference for a 1-10 kΩ potentiometer. One less external PSU in the panel. The control terminals also accept a separate 24V external supply if you prefer isolation. There's a built-in choice between Modbus serial, EtherNet/IP, and Modbus TCP on the communication port, and option slots for Profibus DP, PROFINET, DeviceNet, EtherCAT, CANopen, or Ethernet Powerlink. Rated for pollution degree 2, overvoltage category III, operating altitude up to 4800 m with derating (1% per 100 m above 1000 m). Vibration resistance is 1.5 mm peak-to-peak (2-13 Hz) and 1 gn (13-200 Hz) per IEC 60068-2-6. Shock rating 15 gn for 11 ms. It's built for the real floor – not a lab queen.","metaTitle":"Schneider ATV930U22M3 Altivar Process VFD, 200-240V 3ph 2.2k","metaDescription":"Schneider Electric ATV930U22M3 Altivar Process drive, 200-240V 3-phase, 11.2A normal duty (2.2kW), active production. available via RFQ confirmation for RFQ – verify fit for your B","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Phase":"3 phase","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"With braking chopper Standard version","Category":"US1CP4E22276","Standards":"UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"54.5 dB","Maximum THDI":"<48 % full load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting Mode":"Wall mount","Option Module":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink","Assembly style":"Enclosed","Motor power kW":"2.2 kW normal duty 1.5 kW heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV900","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission Rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device Application":"Industrial Application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 1","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal 2.5...6 mm² AWG 14...AWG 10 Motor screw terminal 2.5...6 mm² AWG 14...AWG 10 DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10","Nbr. of units in pkg.":"1","Volume of cooling air":"10038.7 Gal/hr(US) (38 m3/h)","Nominal Output Current":"11.2 A","IP degree of protection":"IP21","Continuous output current":"11.2 A 4 kHz normal duty 8 A 4 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V","Communication Port Protocol":"Modbus serial EtherNet/IP Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product Specific Application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$481.33","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c48cf12f3c9521480f983584fe8cd32a.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV930U22M3/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings for this drive?","answer":"It operates on 200-240 V 3-phase, delivers 11.2 A continuous (normal duty 2.2 kW) or 8 A (heavy duty 1.5 kW), and comes with an integrated braking chopper."},{"question":"What control supplies does it provide?","answer":"The drive generates 24 V DC for digital inputs and STO (21-27 V), and 10.5 V DC ±5% for a reference potentiometer (1-10 kΩ). You can also inject an external 24 V supply (19-30 V) for the digital inputs."},{"question":"What compliance documentation is available?","answer":"It is CE marked and UL Type 1, meeting UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Typical documentation includes a CE declaration and UL recognition."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV930U22M3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV930U22M3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}