{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV950U75N4EU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV950U75N4EU","canonicalUrl":"https://aoctrl.com/schneider/ATV950U75N4EU","factsUrl":"https://aoctrl.com/api/mcp/products/ATV950U75N4EU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV950U75N4EU, variable speed drive, 3-phase 380-480 V, 7.5 kW normal duty, IP55, with braking chopper and load break switch.","salesMarkdown":"## Built for the route The Schneider ATV950U75N4EU is an Altivar Process drive that doesn't flinch when things get greasy. Rated IP55 and UL type 12, it shrugs off the dust and hose-downs you see on a rotating-equipment route. It's a 3-phase drive for 380...480 V supply, packing a braking chopper and a load break switch right out of the box. The enclosure mounts to the wall, with screw terminals that accept everything from 0.5 mm² control wires up to 10 mm² motor leads. ## What the ratings mean when the line's humming Motor power: 7.5 kW normal duty, 5.5 kW heavy duty. That's the difference between a steady fan load and a pump that digs into the curve. Continuous output current sits at 16.5 A at 4 kHz for normal duty, but drops to 12.7 A at the same frequency for heavy duty — something to watch when you're sizing the motor leads. THDI stays under 48% from 80 to 100% load, so you're not hammering the line with harmonics. Noise level is a reasonable 52 dB — about what a lube pump makes. Up at altitude above 1000 m, derate the current 1% per 100 m; the drive is good to 4800 m if you account for it. Shock rated at 15 gn for 11 ms, and vibration tested to 1.5 mm peak-to-peak down low and 1 gn higher up. It carries CE marking and complies with UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, and functional safety per IEC 61508 and IEC 13849-1.","metaTitle":"Schneider ATV950U75N4EU Altivar Process Drive, 7.5 kW, IP55","metaDescription":"Active-production ATV950U75N4EU, 3-phase 380-480 V, 7.5 kW normal duty drive with IP55 and integrated EMC filter. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Phase":"3 phase","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Variant":"With braking chopper With load break switch","Category":"US1CP4E22277","Standards":"UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated With EMC plate option","Data format":"8 bits, configurable odd, even or no parity","Noise level":"52 dB","Maximum THDI":"<48 % from 80...100 % of load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting Mode":"Wall mount","Option Module":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module communication module Ethernet Powerlink","Assembly style":"Enclosed","Motor power kW":"7.5 kW normal duty 5.5 kW heavy duty","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV900","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission Rate":"10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s","Device Application":"Industrial Application","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Number of addresses":"1...247","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 12","Overvoltage category":"III","Type of polarization":"No impedance","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control screw terminal 0.5...1.5 mm² Motor screw terminal 6...10 mm² Line side screw terminal 4...6 mm² DC bus screw terminal 4...10 mm²","Nbr. of units in pkg.":"1","Nominal Output Current":"16.5 A","IP degree of protection":"IP55","Continuous output current":"16.5 A 4 kHz normal duty 12.7 A 4 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication Port Protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product Specific Application":"Process for industrial","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...104 °F (-15...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,105.00 – $3,869.31","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8b33e5f5bde389b2d24188c2eb976a7.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV950U75N4EU/alternatives.json"},"ai":{"faq":[{"question":"What phase is ATV950U75N4EU?","answer":"It's a 3-phase drive for 380...480 V supply."},{"question":"What are the supply and control voltage requirements?","answer":"Digital inputs need an external 24 V DC supply (19...30 V). There's an internal 10.5 V DC supply for a reference potentiometer (1 to 10 kOhm), and another internal 24 V DC supply (21...27 V) for digital inputs and STO. Insulation test is 1 MOhm at 500 V DC for 1 minute to earth."},{"question":"What compliance standards does ATV950U75N4EU meet?","answer":"CE marked, UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental pollution), and functional safety per IEC 61508 and IEC 13849-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV950U75N4EU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV950U75N4EU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}