{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C11Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C11Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C11Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C11Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980C11Q4X1 regenerative variable speed drive, 110 kW, 380...415 V three-phase, IP23, floor-standing enclosure.","salesMarkdown":"The ATV980C11Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, rated for 110 kW output on a 380...415 V three-phase supply. It ships in a floor-standing IP23 enclosure with a Spacial SF cabinet, main switch, line choke, and graphical operating panel included — essentially a pre-assembled regenerative drive cabinet. THDI stays under 5% at full load per IEEE 519, so it meets harmonic limits without external filtering for most industrial line-ups. The 380...415 V supply range with -10...6 % tolerance means it holds regulation on weak grids — expect dropout below 342 V. Forced convection cooling means the enclosure fans need clearance; vertical mounting within 10° is mandatory. Operating altitude derating starts at 1000 m: 1 % per 100 m up to 3800 m, with additional derating for TT/TN/IT earthing systems above 2000 m. Ambient temperature range is 0...40 °C without derating, 40...50 °C with a derating factor; below 0 °C requires the optional enclosure heating. CE marked, designed to IEC 61800-2 (adjustable speed drives), IEC 61800-3 (EMC), IEC 61800-5-1 (safety), and IEC 60204-1 (machinery safety). EMC immunity includes level 3 for electrostatic discharge, radiated RF, conducted RF, and surge, plus level 4 for fast transients. Environmental resistance covers chemical (3C3), dust (3S3), and humidity (3K3) per IEC 60721-3-3.","metaTitle":"Schneider ATV980C11Q4X1 Altivar Process Regenerative Drive,","metaDescription":"Active-production ATV980C11Q4X1 regenerative variable speed drive, 110 kW at 400 V, IP23 floor-standing enclosure, THDI <5%, IEC 61800 compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C11Q4X1","Marking":"CE","Standards":"IEC 61800-2 IEC 61800-3 IEC 61800-5-1 IEC 60204-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 110 to 90kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus serial EtherNet/IP Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6fbb7957b3da6c0137823b0a118f4b1.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C11Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-110-to-90kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative in this family?","answer":"There is no direct pin-compatible alternative listed because this is the active model. The ATV980 series is the regenerative variant of the Altivar Process ATV900 family; a non-regenerative ATV900 drive would require different wiring and control logic."},{"question":"What are the key ratings for this drive?","answer":"Rated 110 kW at 380...415 V three-phase, 50...60 Hz. THDI <5% at full load. IP23 floor-standing enclosure. Ambient temperature 0...40 °C without derating, up to 50 °C with derating. Altitude derating starts at 1000 m."},{"question":"What compliance documentation is available?","answer":"CE marking, IEC 61800-2/-3/-5-1 and IEC 60204-1 compliance. EMC immunity per IEC 61000-4-2 through -4-6. Environmental resistance per IEC 60721-3-3 classes 3C3, 3S3, 3K3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C11Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C11Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}