{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C13Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C13Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C13Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C13Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980 regenerative system, variable speed drive ATV980C13Q4X1, 132 to 110 kW, 400 V, IP23, CE marked, floor-standing compact enclosure.","salesMarkdown":"The ATV980C13Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, built for asynchronous and synchronous motors. It's the regenerative system variant — meaning it can return energy to the line rather than dumping it as heat across a braking resistor. That's the main differentiator from a standard ATV900 drive: you get the energy-recovery benefit, which matters on applications with overhauling loads like conveyors on a decline, centrifuges, or test stands. Rated supply voltage is 380...415 V at 50/60 Hz, three-phase. The power range is stated as 132 to 110 kW — that's the motor power it can handle, with the regenerative capability baked in. It ships in a floor-standing compact enclosure (IP23), light grey RAL 7035, with forced convection cooling. ## What comes in the box and how it mounts The drive arrives as a complete package: the Spacial SF enclosure with a graphical operating panel in the door, the frequency inverter, main switch, line choke, and terminal blocks for both main supply and motor connections. That's a pre-integrated assembly — you run your incoming power and motor cables to the terminals, not a bare chassis drive you build into a panel. Mounting position is vertical, within ±10 degrees. Cooling is forced convection, so ensure clearance around the enclosure for airflow. The operating temperature range is 0 to 40 °C without derating, with derating required from 40 to 50 °C. Below 0 °C, operation is possible with the optional enclosure heating. Storage temperature spans -25 to 70 °C. ## Standards, EMC, and environmental ruggedness This drive carries CE marking and complies with IEC 61800-2 (adjustable speed drives), IEC 61800-5-1 (safety requirements), IEC 61800-3 (EMC), and IEC 60204-1 (safety of machinery). Pollution degree 2 per IEC 61800-5-1, overvoltage category III. That's the standard spec for industrial power distribution — it expects a clean, dry environment with non-conductive pollution. Total harmonic distortion of input current (THDI) is below 5% at full load, conforming to IEEE 519. That's a strong number — it means the drive's input section is clean enough to avoid nuisance tripping of upstream breakers or overheating transformers in most plants. The EMC immunity levels are specified: electrostatic discharge level 3, radiated RF level 3, fast transient level 4, surge level 3, and conducted RF level 3 per the respective IEC 61000-4-x standards. Environmental classification covers chemical pollution resistance class 3C3, dust pollution resistance class 3S3, and humidity resistance class 3K3 per IEC 60721-3-3. Relative humidity 5 to 95% without condensation. Vibration resistance is 1.5 mm peak-to-peak at 3 to 20 Hz and 0.6 gn at 10 to 200 Hz, meeting class 3M3. Shock resistance is 4 gn for 11 ms per IEC 60068-2-27, class 3M2. ## Altitude derating and communications Standard operation is up to 1000 m without derating. Above that, derate 1% per 100 m up to 2000 m, and continue derating at the same rate up to 3800 m for TT, TN, and IT earthing systems. Extended operation to 4800 m is possible for TT and TN systems with continued derating. If your installation is above 1000 m, factor that into the sizing. Communication ports support EtherNet/IP, Modbus serial, and Modbus TCP. That covers most industrial networks without needing an option card — it talks to a PLC directly over Ethernet or serial. The graphical operator panel in the door gives local control and monitoring. This is a regenerative drive — it's a specific variant within the ATV900 family. A standard ATV900 drive won't recover energy to the line.","metaTitle":"ATV980C13Q4X1 Altivar Process ATV980 Regenerative Drive, 132","metaDescription":"ATV980C13Q4X1 variable speed drive, Altivar Process ATV900 series, regenerative system, 132 to 110 kW, 400V, IP23, CE marked, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C13Q4X1","Marking":"CE","Standards":"IEC 61800-2 IEC 61800-5-1 IEC 61800-3 IEC 60204-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 132 to 110kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a4369edbf61f173fee22ae0b78c988bb.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C13Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-132-to-110kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What is ATV980C13Q4X1's listed marking and standards compliance?","answer":"The ATV980C13Q4X1 carries CE marking and complies with IEC 61800-2, IEC 61800-5-1, IEC 61800-3, and IEC 60204-1."},{"question":"What is the closest alternative to ATV980C13Q4X1 in the ATV900 family?","answer":"The closest alternative is a standard ATV900 drive of similar power rating, but the ATV980C13Q4X1 is the regenerative system variant. A standard ATV900 drive does not recover energy to the line — it requires an external braking resistor for overhauling loads. If your application needs regenerative braking, stick with this order code."},{"question":"Where can I buy ATV980C13Q4X1 and what is the lead time?","answer":"The ATV980C13Q4X1 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C13Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C13Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}