{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C13T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C13T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C13T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C13T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980 regenerative system, variable speed drive, 160/132 kW, 480 V, IP23, CE.","salesMarkdown":"The ATV980C13T4X1 is a Schneider Electric Altivar Process ATV980 regenerative variable speed drive, rated 160/132 kW on 480 V three-phase supply. It ships as a floor-standing compact enclosure with the Spacial SF cabinet, main switch, line choke, and graphical operating panel already fitted — essentially a pre-kitted regenerative drive package for asynchronous or synchronous motors. The IP23 rating (IEC 61800-5-1) means it handles indoor environments with some falling water or dust ingress; forced convection cooling keeps it running without a fan filter change schedule. Supply frequency is 50...60 Hz ±5 %, so it lands on either 50 Hz or 60 Hz networks without reconfiguration. The 480 V ±10 % supply voltage covers 432–528 VAC — standard for North American 480 V three-phase and European 400 V networks (the drive will run on 400 V within tolerance). The 50...60 Hz ±5 % range means it accepts 47–63 Hz, so it works on 50 Hz or 60 Hz grids without a hardware change. The IP23 enclosure is not sealed against hose-down; it's for indoor installation where vertical drip or light splashing occurs. Operating temperature is 0...40 °C without derating, 40...50 °C with derating factor — if the room hits 45 °C, expect a current reduction. Altitude derating starts at 1000 m: 1 % per 100 m up to 2000 m, then continues to 4800 m with the same slope, regardless of earthing system (TT, TN, IT). That means at 2000 m the drive loses 10 % of its rated current; at 3000 m, 20 %. ## Integration notes The drive comes with the Spacial SF enclosure, main switch, line choke, and terminal blocks for main supply and motor — no separate enclosure sourcing needed. Communication ports are EtherNet/IP, Modbus serial, and Modbus TCP, so it drops into most control networks without an extra gateway. The graphical operating panel is mounted in the enclosure door; you can remote-mount it if the panel location is awkward. Vibration resistance is 1.5 mm peak-to-peak at 3–20 Hz and 0.6 gn at 10–200 Hz (IEC 60068-2-6), which is standard for floor-mounted industrial gear — not for direct machine mounting. Shock resistance is 4 gn for 11 ms (IEC 60068-2-27). Pollution degree 2 (IEC 61800-5-1) means only non-conductive pollution occurs, so no special coating required for clean indoor air.","metaTitle":"Schneider ATV980C13T4X1 Altivar Process ATV980, 160/132 kW,","metaDescription":"Schneider ATV980C13T4X1 variable speed drive, Altivar Process ATV980 regenerative system, 160/132 kW, 480 V, IP23, CE, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C13T4X1","Marking":"CE","Standards":"IEC 61800-2 IEC 61800-5-1 IEC 61800-3 IEC 60204-1","description":"Variable speed drive, Altivar Process ATV900, ATV980 Regenerative System,160/132 kW, 480 V, CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f0668bf82ad7d3f7857adadd2e5a438a.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C13T4X1/variable-speed-drive-altivar-process-atv900-atv980-regenerative-system160-132-kw-480-v-ce-ip23/"},"ai":{"faq":[{"question":"What is the closest alternative in the ATV900 family?","answer":"The ATV980 is the regenerative variant. If you don't need regenerative braking, the ATV950 or ATV960 (standard drives) are the functional siblings. They share the same enclosure platform and communication options, but the ATV980 includes the regenerative front end for energy recovery."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C13T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C13T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}