{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C20Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C20Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C20Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C20Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, Regenerative System ATV980, 200 to 160kW, 400V, CE, IP23, floor-standing compact enclosure.","salesMarkdown":"The ATV980C20Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, designed for asynchronous and synchronous motors. It delivers 200 to 160 kW on a 380–415 V three-phase supply, with a THDI below 5% at full load, conforming to IEEE 519 — a solid fit for applications where harmonic compliance is a grid requirement. The unit comes as a floor-standing compact enclosure (IP23) with forced convection cooling, and includes the enclosure, graphical operating panel, main switch, line choke, dv/dt filter choke, and terminal blocks for main supply and motor. That means less procurement of ancillary parts for the panel builder. Rated supply voltage is 380–415 V -10...6 %, three-phase, 50/60 Hz ±5 %. The drive handles a 200–160 kW motor load range; the exact rating depends on the duty cycle and ambient temperature. Operating ambient is 0–40 °C without derating, 40–50 °C with derating factor — plan your enclosure ventilation accordingly. Harmonic performance is a standout: maximum THDI <5% at full load, meeting IEEE 519. That eliminates the need for external harmonic filters in most installations and simplifies grid compliance paperwork. Communication is built-in with Modbus TCP, EtherNet/IP, and Modbus serial — no option card required for these protocols. The drive also meets a full suite of EMC immunity levels (level 3 for ESD, radiated RF, conducted RF, surge; level 4 for fast transients), so it's suited for industrial environments with heavy switching noise. This class of regenerative drive is specified for applications where braking energy is recovered to the line rather than dissipated as heat — think conveyors, cranes, centrifuges, and any high-inertia load with frequent deceleration. The ATV980 variant is the regenerative version of the ATV900 platform, so it's the right pick when energy efficiency targets or line-side power quality standards drive the spec.","metaTitle":"Schneider ATV980C20Q4X1 Altivar Process Regenerative Drive,","metaDescription":"Schneider Electric ATV980C20Q4X1 regenerative drive, 200-160 kW, 400V, IP23, THDI <5%, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C20Q4X1","Marking":"CE","Standards":"IEC 61800-5-1 IEC 61800-3 IEC 61800-2 IEC 60204-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 200 to 160kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/810b2e239fb2e3824e2d319519aff47d.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C20Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-200-to-160kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What are the key ratings I need to know?","answer":"It's a 200–160 kW regenerative drive for 380–415 V three-phase supply, with THDI <5% at full load (IEEE 519), IP23 enclosure, and built-in Modbus TCP, EtherNet/IP, and Modbus serial communication."},{"question":"What compliance standards does it meet?","answer":"The drive is CE marked and conforms to IEC 61800-5-1, IEC 61800-3, IEC 61800-2, and IEC 60204-1. It also meets pollution degree 2 and overvoltage category III."},{"question":"What does the drive come with?","answer":"The package includes the floor-standing enclosure (IP23), graphical operating panel mounted in the door, main switch, line choke, dv/dt filter choke, and terminal blocks for main supply and motor — essentially a ready-to-connect assembly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C20Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C20Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}