{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C25Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C25Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C25Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C25Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, regenerative system ATV980, 250-200kW, 400V, with CE, IP23.","salesMarkdown":"The ATV980C25Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, designed to handle motor loads in the 250 to 200 kW range on a 380-415 V three-phase supply. It comes in a floor-standing compact enclosure with IP23 protection, ready for panel installation with the main switch, line choke, dv/dt filter, and graphical operating panel already fitted. Communication is built in with Modbus TCP, Modbus serial, and EtherNet/IP, so it talks directly to a PLC without an extra gateway card. The supply voltage window is 380-415 V -10...6 %, which covers the common 400 V industrial grid but watch the low end — a weak 380 V line at -10 % is 342 V, and the drive won't hold regulation below that. Harmonic distortion is guaranteed under 5 % THDI at full load per IEEE 519, so you can skip the external harmonic filter for most utility compliance checks. The IP23 enclosure means it's splash-proof but not hose-down; fine for a dry electrical room, not for washdown areas. Cooling is forced convection, so keep the intake clear — stacking another enclosure tight against the side will choke it. ## Integration notes The enclosure is a Spacial SF cabinet, light grey RAL 7035, with the graphical terminal mounted in the door. It ships with the main switch, line choke, dv/dt filter, and terminal blocks for both supply and motor — so you're not chasing loose accessories. Mount it vertical within ±10°, and if you're above 1000 m altitude, derate current 1 % per 100 m up to 4800 m. Operating temperature range is 0-40 °C without derating, 40-50 °C with derating. For cold starts below 0 °C, an enclosure heating option is available. Vibration resistance is 3M3 per IEC 60721-3-3, and shock resistance is 4 gn for 11 ms — rugged enough for most industrial floors.","metaTitle":"Schneider ATV980C25Q4X1 Altivar Process Regenerative Drive,","metaDescription":"Active-production regenerative VFD, 380-415V 3-phase, 250-200kW, IP23 floor-standing enclosure. Modbus TCP/EtherNet/IP, THDI <5%. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C25Q4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 250 to 200kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc575b80a5ffb15369dcb0ee22448035.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C25Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-250-to-200kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What communication protocols does this drive support?","answer":"It supports Modbus TCP, Modbus serial, and EtherNet/IP out of the box."},{"question":"What is the harmonic performance of this drive?","answer":"Total harmonic current distortion (THDI) is less than 5 % at full load, conforming to IEEE 519, so it typically meets utility harmonic limits without an external filter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C25Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C25Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}