{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C25T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C25T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C25T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C25T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV980C25T4X1 regenerative variable speed drive, 280/220 kW, 480 V, CE, IP23, in floor-standing enclosure.","salesMarkdown":"The ATV980C25T4X1 is a regenerative variable speed drive in the Altivar Process ATV900 family, rated 280/220 kW on a 480 V three-phase supply (50...60 Hz ±5 %). It is designed for asynchronous and synchronous motors, and ships as a complete floor-standing enclosure (Spacial SF) with the graphical operating panel, main switch, line choke, dv/dt filter choke, and terminal blocks included. Regenerative operation means it can return braking energy to the line, which matters for overhauling loads or applications where deceleration energy is significant. The IP23 enclosure is intended for indoor installation where some dust ingress is tolerable but not wash-down environments. Supply voltage is 480 V ±10 % three-phase; the drive will accept a nominal 400 VAC system but the power ratings scale with voltage. Operating temperature range is 0...40 °C without derating, and 40...50 °C with derating — no operation below 0 °C unless the optional enclosure heater is fitted. Altitude derating starts at 1000 m: 1 % current reduction per 100 m up to 2000 m, and further derating above that for all earthing systems (TT, TN, IT). The drive carries CE marking and complies with IEC 61800-2 (adjustable speed drives), IEC 61800-3 (EMC), IEC 61800-5-1 (safety), and IEC 60204-1 (electrical equipment of machines). ## Integration notes Mounting is vertical ±10°, forced convection cooling requires clearance around the enclosure for airflow. Communication is via Modbus TCP, Modbus serial, and EtherNet/IP — no fieldbus option card needed for these protocols. EMC immunity meets level 3 for electrostatic discharge, radiated RF, conducted RF, and surge (1.2/50 µs - 8/20 µs), and level 4 for fast transients. Vibration resistance is 1.5 mm peak-to-peak at 3...20 Hz and 0.6 gn at 10...200 Hz (class 3M3). Shock resistance is 4 gn for 11 ms (class 3M2).","metaTitle":"Schneider ATV980C25T4X1 Altivar Process Regenerative Drive,","metaDescription":"ATV980C25T4X1 variable speed drive, Altivar Process ATV900 series, 280/220 kW, 480 V, CE, IP23, active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C25T4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","description":"Variable speed drive, Altivar Process ATV900, ATV980 Regenerative System, 280/220 kW, 480 V, CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4a7d1dc86ebf92c38f44d3e7c0c42de.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C25T4X1/variable-speed-drive-altivar-process-atv900-atv980-regenerative-system-280-220-kw-480-v-ce-ip23/"},"ai":{"faq":[{"question":"What communication protocols does the ATV980C25T4X1 support?","answer":"It supports Modbus TCP, Modbus serial, and EtherNet/IP natively — no additional option card is required for these protocols."},{"question":"What is the IP rating of the ATV980C25T4X1?","answer":"IP23 per IEC 61800-5-1. Suitable for indoor industrial environments where occasional dust ingress is acceptable, but not for wash-down or outdoor installation."},{"question":"What motor types can the ATV980C25T4X1 drive?","answer":"It is designed for both asynchronous (induction) and synchronous motors, as stated in the product destination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C25T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C25T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}