{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C35Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C35Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C35Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C35Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV980C35Q4X1, variable speed drive, regenerative system, 355 to 280 kW, 400 V, IP23, CE marking.","salesMarkdown":"The Schneider ATV980C35Q4X1 is an Altivar Process ATV900 regenerative variable speed drive, rated for 380–415 V three-phase supply, delivering 355 to 280 kW output. It ships as a floor-standing compact enclosure, IP23, with forced convection cooling. The unit includes the Spacial SF enclosure, a graphical operating panel mounted in the door, main switch, line choke, dv/dt filter choke, and terminal blocks for mains and motor — essentially a pre-integrated drive cabinet ready for power wiring. THDI stays under 5 % at full load per IEEE 519, so it meets typical utility harmonic limits without external filtering in most installations. Communication is handled via EtherNet/IP, Modbus TCP, and Modbus serial — three protocols on board, no option card needed for the common fieldbuses. Supply voltage tolerance is 380–415 V -10…+6 %. Operating temperature range is 0…40 °C without derating. Altitude derating starts at 1000 m — 1 % per 100 m up to 3800 m. EMC immunity is specified at level 3 for electrostatic discharge, radiated RF, conducted RF, and surge (1.2/50 µs – 8/20 µs), with fast transient immunity at level 4. Vibration resistance is 1.5 mm peak-to-peak at 3–20 Hz and 0.6 gn at 10–200 Hz, rated 3M3 per IEC 60721-3-3. Marked CE, compliant with IEC 61800-3 (EMC), IEC 60204-1 (safety of machinery), IEC 61800-2 (adjustable speed drives), and IEC 61800-5-1 (electrical safety). Environmental resistance includes chemical class 3C3, dust class 3S3, and humidity class 3K3 per IEC 60721-3-3. Storage temperature range is -25…70 °C.","metaTitle":"Schneider ATV980C35Q4X1 Altivar Process ATV900, 355-280kW, 4","metaDescription":"Active ATV980C35Q4X1 variable speed drive, 380-415V 3-phase, IP23, THDI <5% IEEE 519. Sourced to order via RFQ. Standards IEC 61800-3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C35Q4X1","Marking":"CE","Standards":"IEC 61800-3 IEC 60204-1 IEC 61800-2 IEC 61800-5-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 355 to 280kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"EtherNet/IP Modbus TCP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b2ee050d5398a25564f425695ffe772c.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C35Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-355-to-280kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What are the key standards this drive complies with?","answer":"It complies with IEC 61800-3, IEC 60204-1, IEC 61800-2, and IEC 61800-5-1. It carries CE marking."},{"question":"What communication protocols are built in?","answer":"EtherNet/IP, Modbus TCP, and Modbus serial are all onboard — no additional option card required for these fieldbuses."},{"question":"What is the THDI performance?","answer":"Total harmonic current distortion is under 5 % at full load, conforming to IEEE 519."},{"question":"What is the IP rating and cooling method?","answer":"IP23 enclosure with forced convection cooling. The drive is designed for floor-standing compact installation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C35Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C35Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}