{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C40Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C40Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C40Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C40Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV980 regenerative system, ATV980C40Q4X1, 380…415 V 3-phase, 315 kW, IP23, CE marked.","salesMarkdown":"The ATV980C40Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, built as a compact floor-standing enclosure that includes the frequency inverter, line choke, dv/dt filter choke, main switch, and a graphical operating panel in the door. It is sized for 315 kW output on a 380…415 V three-phase supply, with a THDI below 5 % at full load per IEEE 519. The IP23 enclosure (IEC 61800-5-1) handles indoor installation where some splash or dripping water may occur, but it is not a washdown rating. Supply voltage is 380…415 V at 50/60 Hz ±5 %, three-phase. The drive is rated for both asynchronous and synchronous motors. Ambient temperature range for full rated operation is 0…40 °C without derating; above that, derate linearly up to 50 °C. Below 0 °C, an optional enclosure heating is required. Altitude derating starts at 1000 m — 1 % per 100 m up to 2000 m, and continues the same slope to 4800 m for TT, TN, and IT earthing systems. ## Built-in connectivity and EMC Onboard communication includes Modbus TCP, EtherNet/IP, and Modbus serial. EMC immunity meets level 3 for ESD, radiated RF, and conducted RF; level 4 for fast transients; level 3 for surges (1.2/50 µs – 8/20 µs). The drive is CE marked and complies with IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1. Environmental resistance covers chemical class 3C3, dust class 3S3, and humidity class 3K3 per IEC 60721-3-3.","metaTitle":"Schneider ATV980C40Q4X1 Altivar Process ATV980, 400V, 315kW,","metaDescription":"Active Altivar Process ATV980 regenerative drive, 380-415V 3-phase, 315kW, THDI <5%, IP23, Modbus TCP/EtherNet/IP. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C40Q4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 400 to 315kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cfb602008309a3ca03777630f7857a76.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C40Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-400-to-315kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What communication protocols does this drive support?","answer":"Modbus TCP, EtherNet/IP, and Modbus serial are built in. No additional option card is required for these protocols."},{"question":"What is the harmonic distortion performance?","answer":"Total harmonic current distortion (THDI) is below 5 % at full load, conforming to IEEE 519. This is achieved by the regenerative topology and integrated line choke."},{"question":"What environmental conditions is this drive rated for?","answer":"Operating temperature 0…40 °C without derating (up to 50 °C with derating), storage -25…70 °C, relative humidity 5…95 % non-condensing, altitude up to 1000 m without derating (derating above). Pollution degree 2, overvoltage category III. Vibration resistance 1.5 mm peak-to-peak at 3…20 Hz, shock 4 gn for 11 ms."},{"question":"What is included in the enclosure?","answer":"The drive ships in an IP23 floor-standing enclosure (Spacial SF) with the frequency inverter, main switch, line choke, dv/dt filter choke, terminal blocks for supply and motor, and a graphical operating panel mounted in the door."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C40Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C40Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}