{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C40T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C40T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C40T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C40T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV980C40T4X1, variable speed drive, ATV980 Regenerative System, 450/355 kW, 480 V, CE, IP23.","salesMarkdown":"The ATV980C40T4X1 is a variable speed drive from the Altivar Process ATV900 range, specifically the ATV980 Regenerative System variant. It is rated for 450/355 kW at 480 V supply, comes in a floor-standing enclosure with IP23 protection, and carries CE marking. It is designed for both asynchronous and synchronous motors. Supply voltage is 480 V +/- 10 %, three-phase, 50/60 Hz. The drive is rated for 450 kW (heavy duty) and 355 kW (normal duty) — the lower figure is the continuous rating for standard motor loads, while the higher figure applies to lighter-duty profiles. Operating temperature range is 0 to 40 °C without derating, with derating up to 50 °C. Below 0 °C, an optional enclosure heater is required. Altitude derating starts at 1000 m: 1 % current derating per 100 m up to 2000 m, and further derating up to 4800 m depending on earthing system (TT, TN, IT). The drive includes a dv/dt filter choke, line choke, main switch, and a graphical operating panel in the enclosure door. Communication ports support Modbus TCP, EtherNet/IP, and Modbus serial. Forced convection cooling keeps the power stage within limits. The ATV980C40T4X1 complies with IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1. EMC immunity levels are level 3 for electrostatic discharge, radiated RF, electrical fast transient, surge, and conducted RF, with level 4 for fast transient/burst. Vibration resistance is 1.5 mm peak-to-peak at 3–20 Hz and 0.6 gn at 10–200 Hz, meeting IEC 60721-3-3 class 3M3. Shock resistance is 4 gn for 11 ms.","metaTitle":"Schneider Electric ATV980C40T4X1 Altivar Process ATV980 Rege","metaDescription":"Schneider Electric ATV980C40T4X1 variable speed drive, Altivar Process ATV900 series, ATV980 Regenerative System, 450/355 kW, 480 V, IP23, CE, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C40T4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","description":"Variable speed drive, Altivar Process ATV900, ATV980 Regenerative System, 450/355 kW, 480 V, CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3666f2caae591bc99a015b91dfa3d5e.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C40T4X1/variable-speed-drive-altivar-process-atv900-atv980-regenerative-system-450-355-kw-480-v-ce-ip23/"},"ai":{"faq":[{"question":"What are the key compliance standards for this drive?","answer":"It complies with IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1, and carries CE marking."},{"question":"What communication protocols does it support?","answer":"It supports Modbus TCP, EtherNet/IP, and Modbus serial."},{"question":"What is the operating temperature range?","answer":"0 to 40 °C without derating, with derating up to 50 °C. Below 0 °C requires an optional enclosure heater."},{"question":"What motors can it drive?","answer":"It is designed for both asynchronous and synchronous motors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C40T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C40T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}