{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C45T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C45T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C45T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C45T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980C45T4X1 regenerative variable speed drive, 480 V, IP23, CE marking, floor-standing enclosure.","salesMarkdown":"The ATV980C45T4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, built as a compact floor-standing enclosure with IP23 protection. It's rated for 480 V three-phase supply, delivering regenerative capability for asynchronous and synchronous motors — meaning it can return braking energy to the line, not just dump it as heat. The CE marking and compliance with IEC 60204-1, IEC 61800-5-1, IEC 61800-3, and IEC 61800-2 confirm it meets European machinery and drive standards out of the box. Supply frequency is 50...60 Hz ±5%, so it works on either 50 or 60 Hz mains without adjustment. The 480 V ±10% supply voltage covers common 400 V and 480 V grids. Operating temperature range is 0...40 °C without derating, and 40...50 °C with derating — plan for that if your panel runs hot. Altitude derating starts at 1000 m: 1 % per 100 m up to 2000 m, then continues with the same rate for TT, TN, and IT earthing systems up to 4800 m. Forced convection cooling means the enclosure needs clearance for airflow; vertical mounting ±10° is required. ## Built-in equipment and connectivity The ATV980C45T4X1 ships as a complete package: enclosure (Spacial SF), graphical operating panel in the door, frequency inverter, main switch, line choke, terminal blocks for main supply and motor, and a dv/dt filter choke. Communication is handled via Modbus TCP, EtherNet/IP, and Modbus serial — three protocols on board, no extra option card needed for basic networking. Rated for shock resistance of 4 gn for 11 ms (IEC 60068-2-27, class 3M2) and vibration resistance of 1.5 mm peak-to-peak at 3...20 Hz and 0.6 gn at 10...200 Hz (IEC 60068-2-6, class 3M3). Humidity range is 5...95 % without condensation (IEC 60068-2-3). Environmental classes include chemical pollution resistance 3C3, dust pollution resistance 3S3, and humidity resistance 3K3 per IEC 60721-3-3. Storage temperature spans -25 to 70 °C. ## EMC and insulation EMC immunity is specified at level 3 for electrostatic discharge (IEC 61000-4-2), radiated RF (IEC 61000-4-3), surge (IEC 61000-4-5), and conducted RF (IEC 61000-4-6), and level 4 for fast transients (IEC 61000-4-4). Insulation tested at 1 MOhm, 500 V DC for 1 minute to earth.","metaTitle":"Schneider ATV980C45T4X1 Altivar Process ATV980, 480 V, IP23","metaDescription":"ATV980C45T4X1 is an active Altivar Process ATV980 regenerative drive, 480 V, IP23, with CE marking and IEC compliance. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C45T4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-5-1 IEC 61800-3 IEC 61800-2","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980 -500/400 kW, 480 V with CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce09e6678cf853354011c7e69f4827ce.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C45T4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-500-400-kw-480-v-with-ce-ip23/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C45T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C45T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}