{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C50T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C50T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C50T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C50T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980C50T4X1 regenerative variable speed drive, 560/450 kW, 480 V, IP23, CE.","salesMarkdown":"The ATV980C50T4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, rated for 560 kW (heavy duty) / 450 kW (normal duty) on a 480 V three-phase supply. It ships as a compact floor-standing enclosure (IP23 per IEC 61800-5-1) with the graphical operating panel, main switch, line choke, dv/dt filter choke, and motor terminals already integrated — a near turnkey package for motor control centers or standalone installations. The 480 V +/- 10 % supply at 50/60 Hz +/- 5 % feeds a three-phase input. Forced convection cooling handles the thermal load; the drive operates from 0 to 40 °C without derating, and from 40 to 50 °C with a derating factor applied. ## Standards, compliance, and environmental robustness The drive is CE marked and designed to IEC 61800-2 (adjustable speed power drive systems), IEC 61800-3 (EMC), IEC 61800-5-1 (safety), and IEC 60204-1 (electrical equipment of machines). EMC immunity meets level 3 for electrostatic discharge, radiated RF, surge, and conducted RF, and level 4 for fast transients — suitable for industrial environments with moderate to high electrical noise. Environmental resistance covers chemical pollution class 3C3, dust class 3S3, and humidity class 3K3 per IEC 60721-3-3. Vibration resistance is 1.5 mm peak-to-peak at 3–20 Hz and 0.6 gn at 10–200 Hz (class 3M3). Shock resistance is 4 gn for 11 ms (class 3M2). Altitude derating begins at 1000 m: 1 % per 100 m up to 4800 m, with earthing system (TT, TN, IT) considered above 2000 m. ## Integration and communication The drive supports Modbus serial, EtherNet/IP, and Modbus TCP natively — no option card needed for these protocols. The provided enclosure (Spacial SF, light grey RAL 7035) includes a graphical operating panel mounted in the door, main supply and motor terminal blocks, a line choke, and a dv/dt filter choke. This reduces external component count and wiring for the panel builder. Operating position is vertical within ±10°. Relative humidity range is 5–95 % without condensation. The drive is intended for asynchronous and synchronous motors, making it flexible across pump, fan, conveyor, and general process applications.","metaTitle":"ATV980C50T4X1 Altivar Process ATV980 Regenerative Drive, 560","metaDescription":"ATV980C50T4X1 variable speed drive, Altivar Process ATV900 series, 560/450 kW, 480 V, IP23, CE marked, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C50T4X1","Marking":"CE","Standards":"IEC 61800-2 IEC 61800-3 IEC 61800-5-1 IEC 60204-1","description":"Variable speed drive, Altivar Process ATV900, ATV980 Regenerative System, 560/450 kW, 480 V, CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"Modbus serial EtherNet/IP Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09d8aa8379035c7b76ff2e44990574e1.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C50T4X1/variable-speed-drive-altivar-process-atv900-atv980-regenerative-system-560-450-kw-480-v-ce-ip23/"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"The ATV980C50T4X1 is rated 560 kW (heavy duty) / 450 kW (normal duty) at 480 V three-phase, 50/60 Hz. Enclosure is IP23, cooling is forced convection, and ambient operating range is 0 to 40 °C without derating."},{"question":"What communication protocols does this drive support?","answer":"It supports Modbus serial, EtherNet/IP, and Modbus TCP natively. No additional option cards are required for these protocols."},{"question":"What standards does the ATV980C50T4X1 comply with?","answer":"It is CE marked and designed to IEC 61800-2, IEC 61800-3, IEC 61800-5-1, and IEC 60204-1. Overvoltage category III and pollution degree 2 per IEC 61800-5-1 apply."},{"question":"What is included with the drive in the enclosure?","answer":"The floor-standing enclosure (IP23) includes the graphical operating panel, main switch, line choke, dv/dt filter choke, main supply terminal block, and motor terminal block. The drive is essentially a pre-integrated package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C50T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C50T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}