{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C56Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C56Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C56Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C56Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV980 Regenerative System, ATV980C56Q4X1, 560 to 450kW, 400V, IP23, with CE.","salesMarkdown":"The ATV980C56Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, designed for 380–415 V three-phase supplies and rated for 560 kW (heavy duty) down to 450 kW (normal duty). It ships as a floor-standing compact enclosure (IP23) with forced convection cooling, and includes the line choke, dv/dt filter choke, main switch, and a graphical operator panel mounted in the door — so it arrives as a near-complete drive cabinet, not a bare chassis. Built for both asynchronous and synchronous motor control, it complies with IEC 61800-5-1, IEC 60204-1, IEC 61800-3, and IEC 61800-2. The drive is CE marked and carries pollution degree 2, overvoltage category III, and EMC immunity at test level 3 or 4 across the key transient and radiated-field tests. ## Communication and integration Three communication ports are built in: Modbus serial, Modbus TCP, and EtherNet/IP. No option card needed for the common industrial Ethernet protocols. The drive also includes a graphical operator panel on the enclosure door, so commissioning and monitoring do not require a laptop for basic tasks. ## Environmental and installation constraints Rated for 0 to 40 °C ambient without derating, and 40 to 50 °C with derating. Below 0 °C, operation is possible with the optional enclosure heating. Altitude derating starts at 1000 m: 1 % current derating per 100 m up to 2000 m, and the same slope continues to 3800 m (or 4800 m for TT/TN/IT systems). If the installation is above 1000 m, factor that into the motor current requirement. The enclosure is rated IP23. Vibration resistance is 1.5 mm peak-to-peak at 3–20 Hz and 0.6 gn at 10–200 Hz.","metaTitle":"Schneider ATV980C56Q4X1 Altivar Process ATV900 VSD, 560kW, I","metaDescription":"Active ATV980 regenerative drive, 380-415V 3-phase, 560kW, IP23, THDI <5%, Modbus TCP/EtherNet/IP. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C56Q4X1","Marking":"CE","Standards":"IEC 61800-5-1 IEC 60204-1 IEC 61800-3 IEC 61800-2","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 560 to 450kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f8662506d4f531648b97cd49fc9ea3e.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C56Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-560-to-450kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What are the key ratings of the ATV980C56Q4X1?","answer":"It is a 380–415 V three-phase regenerative drive rated 560 kW (heavy duty) to 450 kW (normal duty), with THDI below 5 % at full load, IP23 enclosure, and built-in Modbus TCP, EtherNet/IP, and Modbus serial communication."},{"question":"What compliance standards does the ATV980C56Q4X1 meet?","answer":"It complies with IEC 61800-5-1, IEC 60204-1, IEC 61800-3, and IEC 61800-2, is CE marked, and carries EMC immunity at test level 3 or 4 for electrostatic discharge, radiated fields, fast transients, surges, and conducted RF."},{"question":"What communication protocols are supported?","answer":"Modbus serial, Modbus TCP, and EtherNet/IP are all built in — no option cards required for these protocols."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C56Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C56Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}