{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C63Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C63Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C63Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C63Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, regenerative system ATV980, variable speed drive, 630 to 500kW, 400V, IP23, CE marking.","salesMarkdown":"The ATV980C63Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, rated for 630 to 500 kW on a 380–415 V three-phase supply. It ships in a floor-standing compact enclosure (IP23) with the main switch, line choke, dv/dt filter choke, and a graphical operating panel already integrated — essentially a pre-wired drive cabinet, not a bare chassis. Built for asynchronous and synchronous motors, it complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 60204-1 (machinery), and IEC 61800-2 (power drive systems). Total harmonic current distortion stays under 5 % at full load per IEEE 519, which means it meets utility-grade harmonic limits without external filtering on most installations. Supply voltage is 380–415 V three-phase, -10 % / +6 %. That covers the common 400 V industrial grid across Europe and much of Asia. The 50/60 Hz ±5 % input frequency means it works on either standard without reconfiguration. Forced-convection cooling keeps the interior clear of fan filters that would need regular replacement. Altitude derating is explicit: full rated current up to 1000 m, then 1 % per 100 m up to 4800 m, with earthing system restrictions above 2000 m (TT, TN, IT). If the installation is above 1000 m, factor the derating into the motor sizing. ## Communications and environmental robustness Onboard communication includes Modbus TCP, Modbus serial, and EtherNet/IP — no option card needed for these three protocols. That covers most PLC ecosystems (Schneider, Rockwell, Siemens via gateway) without extra hardware. Environmental classification is 3C3 (chemical), 3S3 (dust), and 3K3 (humidity) per IEC 60721-3-3, with 5–95 % relative humidity without condensation. Vibration resistance meets 3M3, shock resistance 3M2 (4 g for 11 ms). Storage temperature range is -25 to 70 °C; operating range is 0 to 40 °C without derating, 40 to 50 °C with derating.","metaTitle":"Schneider ATV980C63Q4X1 Altivar Process ATV900, 630-500kW, 4","metaDescription":"Active ATV980C63Q4X1 regenerative drive, 380-415V 3-phase, 630-500kW, IP23, THDI <5%, Modbus TCP/EtherNet/IP. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C63Q4X1","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 60204-1 IEC 61800-2","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 630 to 500kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP Modbus serial EtherNet/IP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d9be2be27bcb8684fb4413d7a333964a.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C63Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-630-to-500kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What communication protocols does this drive support?","answer":"It supports Modbus TCP, Modbus serial, and EtherNet/IP onboard."},{"question":"What is the THDI specification and why does it matter?","answer":"Total harmonic current distortion is less than 5 % at full load, conforming to IEEE 519. That means the drive meets utility harmonic limits without external filters in most installations."},{"question":"What is the IP rating and enclosure type?","answer":"IP23 per IEC 61800-5-1, in a floor-standing compact enclosure. Suitable for indoor electrical rooms, not for washdown environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C63Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C63Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}