{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C71Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C71Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C71Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C71Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, regenerative system ATV980, 710 to 560kW, 400V, with CE, IP23 enclosure.","salesMarkdown":"The ATV980C71Q4X1 is a regenerative variable speed drive from the Altivar Process ATV900 family, rated 710 to 560 kW on a 380–415 V three-phase supply (-10...6 %). It ships as a floor-standing compact enclosure (IP23) with a built-in dv/dt filter choke, line choke, main switch, and a graphical operating panel on the door — essentially a pre-integrated regenerative drive package for motor control panels. Supply frequency is 50...60 Hz ±5 %, so it matches standard mains globally. Total harmonic current distortion (THDI) is under 5 % at full load per IEEE 519 — that's the key number for meeting grid codes without external filtering. The IP23 enclosure allows indoor installation with some drip and dust protection; forced convection cooling means you need clearance around the cabinet for airflow. Operating altitude derates current 1 % per 100 m above 1000 m, and the drive is rated for overvoltage category III on a TN/TT/IT earthing system up to 4800 m with derating. Ambient temperature range is 0...40 °C without derating, 40...50 °C with derating factor. Below 0 °C an optional enclosure heater is needed. The drive handles shock to 4 gn for 11 ms and vibration to 1.5 mm peak-to-peak at 3–20 Hz, meeting IEC 60721-3-3 class 3M3 — rugged enough for most industrial floors. ## Built-in communications and I/O Onboard protocols include Modbus TCP, EtherNet/IP, and Modbus serial — no option card needed for the common fieldbuses. The drive is designed for both asynchronous and synchronous motors, giving flexibility for retrofits or new machine designs.","metaTitle":"Schneider ATV980C71Q4X1 Altivar Process ATV980 Regenerative","metaDescription":"Active-production regenerative drive, 710 to 560kW, 380-415V, THDI <5%, IP23, with built-in dv/dt choke, line choke, and Modbus/EtherNet/IP. Sourced to order — RFQ for ETA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C71Q4X1","Marking":"CE","Standards":"IEC 61800-2 IEC 60204-1 IEC 61800-5-1 IEC 61800-3","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 710 to 560kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"Modbus TCP EtherNet/IP Modbus serial","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/645412ebb7c5b017af6ca243aa7d23b7.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C71Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-710-to-560kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What compliance documentation does this drive carry?","answer":"It is CE-marked and designed to IEC 61800-2, IEC 60204-1, IEC 61800-5-1, and IEC 61800-3. Pollution degree 2 per IEC 61800-5-1. EMC immunity meets level 3 for electrostatic discharge, radiated RF, and fast transients, and level 4 for surges."},{"question":"What is the THDI performance?","answer":"Total harmonic current distortion is under 5 % at full load, conforming to IEEE 519 — this means the drive meets typical grid harmonic limits without external filters in most installations."},{"question":"What comes in the enclosure?","answer":"The floor-standing IP23 cabinet includes the frequency inverter, main switch, line choke, dv/dt filter choke, terminal blocks for supply and motor, and a graphical operating panel on the door."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C71Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C71Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}