{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C80Q4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C80Q4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C80Q4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C80Q4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980 regenerative drive, ATV980C80Q4X1, 800 to 630kW, 380-415 V three-phase, IP23, CE.","salesMarkdown":"## Drive selection memo — regenerative system for 400 V class The ATV980C80Q4X1 is a variable speed drive from the Altivar Process ATV900 series, specifically the ATV980 regenerative variant, delivering 800 to 630 kW on a 380...415 V three-phase supply. This is a floor-standing compact enclosure, pre-configured with the line choke, dv/dt filter choke, main switch, and graphical operating panel mounted in the door — it arrives as a near-complete drive cabinet, not a bare chassis. Rated for asynchronous and synchronous motors, it handles the regenerative energy from overhauling loads (cranes, conveyors on a decline, test stands) by feeding it back to the line rather than dumping it as heat across a braking resistor. The total harmonic current distortion stays under 5 % at full load, compliant with IEEE 519, which keeps the plant's distribution clean without needing a separate active filter. The 380...415 V -10...6 % supply range covers the standard European 400 V class with enough headroom for weak grids. IP23 means the enclosure is drip-proof but not washdown-rated — suitable for a clean electrical room or a controlled industrial hall, not for direct spray-down areas. Forced convection cooling requires clearance around the cabinet for airflow; the operating position is vertical ±10 degrees. The vibration and shock ratings (1.5 mm peak-to-peak at 3...20 Hz, 4 gn for 11 ms) matter for applications like marine or mobile plant equipment where the drive sees continuous low-frequency vibration. Altitude derating starts at 1000 m — 1 % per 100 m for all earthing systems (TT, TN, IT) up to 3800 m, and continues to 4800 m with the same rate. If the drive is going into a high-altitude installation, factor that into the motor current rating.","metaTitle":"Schneider ATV980C80Q4X1 Altivar Process ATV980, 800-630kW, 4","metaDescription":"Schneider Electric ATV980C80Q4X1 variable speed drive, Altivar Process ATV980 regenerative system, 800 to 630kW, 380-415V 3-phase, IP23, CE marked, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C80Q4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-5-1 IEC 61800-2 IEC 61800-3","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980, 800 to 630kW, 400V, with CE, IP23","Maximum THDI":"<5 % full load conforming to IEEE 519","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e08099e516a58ca220aabf32b3fe0769.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C80Q4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-800-to-630kw-400v-with-ce-ip23/"},"ai":{"faq":[{"question":"What compliance standards does the ATV980C80Q4X1 meet?","answer":"It is CE marked and complies with IEC 60204-1, IEC 61800-5-1, IEC 61800-2, and IEC 61800-3. It also meets IEEE 519 for total harmonic current distortion below 5 % at full load."},{"question":"What is the supply voltage and power range for this drive?","answer":"It operates on a 380...415 V three-phase supply, -10...6 %, and covers the 800 to 630 kW power range. The drive is a regenerative system, feeding braking energy back to the line."},{"question":"What is the enclosure rating and cooling method?","answer":"IP23 per IEC 61800-5-1 with forced convection cooling. It is a floor-standing compact enclosure suitable for indoor electrical rooms, not washdown environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C80Q4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C80Q4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}