{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV980C80T4X1","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV980C80T4X1","canonicalUrl":"https://aoctrl.com/schneider/ATV980C80T4X1","factsUrl":"https://aoctrl.com/api/mcp/products/ATV980C80T4X1","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV980C80T4X1 regenerative variable speed drive, 900/710 kW at 480 V, IP23, CE marked.","salesMarkdown":"The Schneider ATV980C80T4X1 is a regenerative variable speed drive from the Altivar Process ATV900 series, rated at 900/710 kW on a 480 V three-phase supply. It ships as a complete floor-standing compact enclosure (IP23) that includes the Spacial SF enclosure, a graphical operating panel mounted in the door, the main switch, line choke, dv/dt filter choke, and terminal blocks for main supply and motor — essentially a pre-integrated regenerative drive cabinet for industrial process applications. It drives both asynchronous and synchronous motors, with forced convection cooling and an operating range of 0 to 40 °C without derating, extending to 50 °C with a derating factor. Below 0 °C, an optional enclosure heater is required. ## Regenerative capability and supply details This is a regenerative drive — it returns braking energy to the line, which is the key differentiator from a standard ATV900 drive. Rated supply voltage is 480 V ±10% at 50/60 Hz ±5%. ## Communications and environmental resilience Onboard communication includes EtherNet/IP, Modbus serial, and Modbus TCP — no option card needed for these protocols. The drive is rated for chemical pollution resistance class 3C3, dust resistance 3S3, and humidity resistance 3K3 per IEC 60721-3-3, which means it can tolerate industrial atmospheres with moderate chemical and dust exposure. EMC immunity meets level 3 for electrostatic discharge, radiated RF, surge, and conducted RF, and level 4 for fast transients (IEC 61000-4-4). Operating altitude is 1000 to 2000 m with 1% current derating per 100 m; above 2000 m up to 3800 m the derating applies for TT, TN, and IT earthing systems, and up to 4800 m for TT and TN systems. ## Standards compliance and lifecycle The drive carries CE marking and complies with IEC 60204-1 (safety of machinery), IEC 61800-5-1 (adjustable speed drives – safety), IEC 61800-2 (power drive systems – rating), and IEC 61800-3 (EMC). Vibration resistance is rated 3M3 per IEC 60721-3-3, shock resistance 3M2 per IEC 60721-3-3 and 4 gn for 11 ms per IEC 60068-2-27. Product lifecycle status is active — no end-of-life or last-time-buy notice.","metaTitle":"Schneider ATV980C80T4X1 Altivar Process 900 Regenerative Dri","metaDescription":"Active ATV980C80T4X1 regenerative drive from Schneider Altivar Process 900. 900/710 kW at 480 V, IP23, includes enclosure, HMI, line choke, dv/dt filter. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV980C80T4X1","Marking":"CE","Standards":"IEC 60204-1 IEC 61800-5-1 IEC 61800-2 IEC 61800-3","description":"Variable speed drive, Altivar Process ATV900, Regenerative System ATV980 -900/710 kW, 480 V with CE, IP23","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV980","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Product destination":"asynchronous motors synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V +/- 10 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fbc9c8849688e5f91e93c184dcf4221e.pdf","sourceUrl":"https://www.se.com/ae/en/product/ATV980C80T4X1/variable-speed-drive-altivar-process-atv900-regenerative-system-atv980-900-710-kw-480-v-with-ce-ip23/"},"ai":{"faq":[{"question":"What marking and standards does the ATV980C80T4X1 carry?","answer":"It carries CE marking and complies with IEC 60204-1, IEC 61800-5-1, IEC 61800-2, and IEC 61800-3."},{"question":"What is the supply voltage and frequency range?","answer":"Rated supply voltage is 480 V ±10% at 50/60 Hz ±5%, three-phase."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV980C80T4X1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV980C80T4X1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}