{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C11N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C11N6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C11N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C11N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ATV9A0C11N6, Altivar Process ATV900, modular variable speed drive, 75 kW normal duty, 110 A line current, integrated EMC filter C3, safe torque off SIL 3.","salesMarkdown":"The Schneider Electric ATV9A0C11N6 is a current-production modular drive from the Altivar Process ATV900 family. It delivers 75 kW (normal duty) or 55 kW (heavy duty) at 500 V, drawing 110 A or 83 A line current respectively. That normal duty rating maps to constant-torque loads like conveyors and mixers; the heavy-duty rating covers variable-torque pumps and fans. Apparent power is 95 kVA normal, 72 kVA heavy. Switching frequency is adjustable from 2 to 4.9 kHz, with derating at the high end — keep that in mind if you need near-silent operation but can't sacrifice output current. Prospective line Isc is 50 kA, so the drive holds its own in high-fault-current panels. ## Controls, safety, and fieldbus Safe Torque Off (STO) comes standard with SIL 3 capability, satisfying Category 3 PL e per IEC 13849-1. That means no external safety contactor for stop functions — one less component in the cabinet and one less wiring step. The drive also includes thermal protection for both motor and drive, plus phase loss and overspeed detection on the control circuit. Communication is flexible: the base drive ships with Modbus TCP slave and Modbus serial (RTU/ASCII) onboard. Slot A accepts a Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen card; Slot B and Slot C handle encoder interfaces (digital, analog, resolver) and I/O or relay extension modules. That means you can match the plant network without buying a different drive SKU. Internal supply rails are provided: 24 V DC for digital inputs and STO (21–27 V), and a 10.5 V DC ±5 % reference for a 1–10 kΩ potentiometer. The digital input supply can be fed from an external 24 V source (19–30 V) if you prefer to offload the control transformer. ## Mounting, cooling, and environmental Cabinet mount only — IP00 module intended for IP21 or IP54 enclosures. Cooling is forced convection, so plan for adequate airflow around the heatsink. Operating altitude to 2000 m with current derating above 1000 m; pollution degree 2. Vibration resistance is 0.5 gn from 13 to 200 Hz, 1.5 mm peak-to-peak from 2 to 13 Hz. Those numbers are friendly for standard panel mounting on a backplate. Line side uses M10 bolts; motor connections are M10 bars. Control wiring lands on removable screw terminals accepting 0.5–1.5 mm² (AWG 20–16). The integrated EMC filter is rated for up to 300 m of motor cable at C3 category — enough for most distributed drives without an external output choke.","metaTitle":"ATV9A0C11N6 Altivar Process ATV900, 75 kW, 110 A","metaDescription":"Current production ATV9A0C11N6 drive, 75 kW normal duty, integrated EMC filter C3, STO SIL 3, Modbus TCP. Sourced to order. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV9A0C11N6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"69 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 500 V, 75 kW","Line current":"110.0 A 500 V normal duty) 83.0 A 500 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"95.0 kVA at 500 V normal duty 72.0 kVA at 500 V heavy duty","Motor power kW":"75.0 kW at 500 V normal duty 55.0 kW at 500 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"125.0 A at 2.5 kHz normal duty 105.0 A at 2.5 kHz heavy duty","Maximum transient current":"150.0 A 60 s normal duty) 157.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV9A0C11N6/variable-speed-drive-altivar-process-atv900-apm-single-500-v-75-kw/"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"At 500 V, it delivers 75 kW normal duty (110 A line current) and 55 kW heavy duty (83 A). Apparent power is 95 kVA normal and 72 kVA heavy."},{"question":"What communication protocols are natively supported?","answer":"Modbus TCP and Modbus serial (RTU) are built in. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen cards. Slots B and C handle encoder and I/O expansion."},{"question":"What safety functions does the drive include?","answer":"Safe Torque Off (STO) certified to SIL 3 per IEC 61508 and IEC 13849-1, plus thermal and phase-loss protections for both motor and drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C11N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C11N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}